Evidence map›Paper›PMID 39973846›Full record

ArticleTechnology and health care : official journal of the European Society for Engineering and Medicine2025

Machine learning for improved medical device management: A focus on defibrillator performance.

Lemana Spahić, Luka Jeremić, Ivana Lalatović, Tatjana Muratović, Amra Džuho, Lejla Gurbeta Pokvić, Almir Badnjević

Expression of concernAbstract read
PubMed Publisher
In one paragraph

Article in Technology and health care : official journal of the European Society for Engineering and Medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It carries an expression of concern. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Lemana SpahićResearch Institute Verlab for Biomedical Engineering, Medical Devices and Artificial Intelligence, Sarajevo, Bosnia and Herzegovina.ORCID 0000-0002-0922-6335
Luka JeremićUniversity of Donja Gorica, Podgorica, Montenegro.
Ivana LalatovićUniversity of Donja Gorica, Podgorica, Montenegro.
Tatjana MuratovićUniversity of Donja Gorica, Podgorica, Montenegro.
Amra DžuhoResearch Institute Verlab for Biomedical Engineering, Medical Devices and Artificial Intelligence, Sarajevo, Bosnia and Herzegovina.
Lejla Gurbeta PokvićResearch Institute Verlab for Biomedical Engineering, Medical Devices and Artificial Intelligence, Sarajevo, Bosnia and Herzegovina.
Almir BadnjevićFaculty of Pharmacy, University of Sarajevo, Sarajevo, Bosnia and Herzegovina.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BackgroundPoorly regulated and insufficiently maintained medical devices (MDs) carry high risk on safety and performance parameters impacting the clinical effectiveness and efficiency of patient diagnosis and treatment. After the MD directive (MDD) had been in force for 25 years, in 2017 the new MD Regulation (MDR) was introduced. One of the more stringent requirement is a need for better control of MD safety and performance post-market surveillance mechanisms.ObjectiveTo address this, we have developed an automated system for management of MDs, based on their safety and performance measurement parameters, that use machine learning algorithm as a core of its functioning.MethodsIn total, 1997 samples were collected during the inspection process of defibrillator inspections performed by an ISO 17020 accredited laboratory at various healthcare institutions in Bosnia and Herzegovina. This paper presents solution developed for defibrillators, but proposed system is scalable to any other type of MDs, both diagnostic and therapeutic.ResultsVarious machine learning algorithms were considered, including Decision Tree (DT), Random Forest (RF), Naïve Bayes (NB) and Logistic Regression (LR). In addition, random forest regressor and XG Boost algorithms were tested for their predictive capabilities in the field of defibrillator output error prediction. These algorithms were selected because of their ability to handle large datasets and their potential for achieving high prediction accuracy. The highest accuracy achieved on this dataset was 94.8% using the Naive Bayes algorithm. The XGBoost Regressor with its r