ArticleEuropean journal of medical research2025
Invention of a new percutaneous closure technique for vascular haemostasis in percutaneous veno-arterial extracorporeal membrane oxygenation.
Article in European journal of medical research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
objectiveTo assess the feasibility and safety of a novel closure technique, namely the parallel closure technique (Par-CT), in which the sheath is placed parallel to the ProGlide system during veno-arterial extracorporeal membrane oxygenation (VA-ECMO) to enhance the efficiency of percutaneous vascular haemostasis.
methodsThe abdominal aortas of goats were punctured with a 17F sheath to simulate arterial cannula vascular access for VA-ECMO, and the Par-CT was used to achieve vascular haemostasis. In five goats, the abdominal aorta was punctured with a 17F sheath and then a 6 to 10F vascular sheath was introduced. This resulted in a smaller vascular rupture area and successful closure of the aortic rupture using the Par-CT.
resultsIf the sheath tube that was introduced was < 8 F, the puncture site could not be closed and would therefore have to be resutured and the Par-CT would have to be repeated. However, the puncture site could be sutured appropriately if the sheath tube that was introduced was ≥ 8F.
conclusionsThis study suggested that the Par-CT is both safe and effective for haemostasis after weaning from VA-ECMO.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.