Evidence map›Paper›PMID 39968949›Full record

ArticleJournal of applied clinical medical physics2025

From 2D to 3D gamma passing rate tolerance and action limits for patient-specific quality assurance in volumetric-modulated arc therapy.

Christos Zarros, George Patatoukas, Nikos Kollaros, Marina Chalkia, Andromachi Kougioumtzopoulou, Vasilios Kouloulias, Kalliopi Platoni

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Christos ZarrosMedical Physics Unit, Second Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon General University Hospital, Haidari, Athens, Greece.ORCID https://orcid.org/0009-0001-9614-5962
George PatatoukasMedical Physics Unit, Second Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon General University Hospital, Haidari, Athens, Greece.
Nikos KollarosMedical Physics Unit, Second Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon General University Hospital, Haidari, Athens, Greece.
Marina ChalkiaMedical Physics Unit, Second Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon General University Hospital, Haidari, Athens, Greece.ORCID https://orcid.org/0000-0002-7796-6001
Andromachi KougioumtzopoulouRadiation Therapy Unit, Second Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon General University Hospital, Haidari, Athens, Greece.
Vasilios KoulouliasRadiation Therapy Unit, Second Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon General University Hospital, Haidari, Athens, Greece.
Kalliopi PlatoniMedical Physics Unit, Second Department of Radiology, Medical School, National and Kapodistrian University of Athens, Attikon General University Hospital, Haidari, Athens, Greece.ORCID https://orcid.org/0000-0003-2977-7895

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundVolumetric modulated arc therapy (VMAT) requires an accurate patient-specific quality assurance (PSQA) program. In clinical practice, this is usually performed using the γ-index and the two-dimensional gamma passing rate (2D %GP). A three-dimensional (3D) index incorporating the patient anatomy could be more useful for the 3D dose distribution verification. PURPOSE: The current study demonstrates a thorough investigation of VMAT PSQA treatment plans by examining the correlation between 3D Gamma passing rate (%GP) and 2D %GP. The aim was to establish the tolerance limits (TL) and action limits (AL) that could be adopted in clinical practice. MATERIALS AND

methodsPSQA was performed for 67 head and neck (H&N) and 69 prostate treatment plans, using an appropriate phantom and the γ-index method. The 3%/2  mm acceptance criterion was used. Treatment plans' 2D% GP and 3D %GP values were collected and correlated with individual 3D %GP values of planning target volume (PTV) and organs at risk (OARs). Institutional TL and AL of both 2D %GP and 3D %GP were established using 30 prostate and 30 H&N treatment plans, as per recommendations proposed by AAPM TG-218.

resultsA moderate correlation was observed between 2D %GP and 3D %GP of the treatment plans. Τhe correlations demonstrated a stronger association for the 3D %GP than for the 2D %GP with respect to the 3D %GP of the individual structures considered. The TL for the 3D %GP (both plan and individual) and the plans' 2D %GP were generally more stringent, while the AL showed a wider range compared to the corresponding limits suggested by the TG-218 protocol for plan 2D %GP.

conclusionsInstitution-specific 3D %GP as well as TL and AL for treatment plan, PTV and OARs could be incorporated in the PSQA procedure in synergy with the 2D evaluation, as they can provide a more-in-depth-view of the treatment quality.

Indexed as

Gamma RaysHead and Neck NeoplasmsOrgans at RiskPhantoms, ImagingProstatic NeoplasmsQuality Assurance, Health CareRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedHumansMaleRadiotherapy Dosageaction limits (AL)Gamma passing rate (%GP)tolerance Limits (TL)VMAT PSQA

Identifiers

PMID39968949
PMCPMC12148792

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.