Preparation of dual mode spectroscopic system for testing: Analysis of sample holder and investigation of intensity noise.
Article in Heliyon, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Absorption spectroscopy is combined with the principle of multiple wavelengths to develop a biomedical sensing mechanism, laid by two Fibre Bragg Gratings. It is essential to incorporate a sample holder in the setup in which the substances can be tested, necessitating its complete investigation without and with the holder, in both directions. The average losses of the fibre junctions are 0.44 and 0.18 dB, respectively, with accuracy of ±0.2 dB which lies within the intensity profile specified by the manufacturer (0.3 dB). Next, the spectral profiles and its respective factors (slope, threshold, mode spacing, intensity levels) of both systems are compared and thoroughly investigated on technical grounds, to examine any anticipated issues for the sensor's operation. Afterwards, we place the holder in the laser setup and check its efficiency by comparing it the intensity profiles of the system without it, under identical parametric values. The average Relative Intensity Noise is found to be consistently low and analogous in both setups, with scientific justifications. Repetition in the forward and reverse directions, and swapping the positions of the lenses, the outcomes show homogenous patterns, which provides conclusive approval with specified parametric regulations in this work.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.