ArticleEuropean radiology experimental2025
Sub-1-min relaxation-enhanced non-contrast non-triggered cervical MRA using compressed SENSE with deep learning reconstruction in healthy volunteers.
Article in European radiology experimental, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Free-breathing, blood-flow-independent, three-dimensional relaxation-enhanced angiography without contrast and triggering (REACT) for aorta measurement and diagnosis in patients with aortic disease: a comparison with computed tomography angiography.Quantitative imaging in medicine and surgery · 2026Article
- Improvement in Image Quality and Efficiency of Non-contrast Thoracic MR Angiography: Comparison of a Highly Accelerated Dixon-based Technique with the Conventional Fat-suppressed Technique.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2026Article
- Vascular Eagle Syndrome in Elderly Patients Diagnosed by Dynamic Magnetic Resonance Angiography: A Case Report and Literature Review.NMC case report journal · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundWe evaluated the acceleration of a three-dimensional isotropic flow-independent magnetic resonance angiography (MRA) (relaxation-enhanced angiography without contrast and triggering, REACT) of neck arteries using compressed SENSE (CS) combined with deep learning (adaptive intelligence, AI)-based reconstruction (CS-AI).
methodsThirty-four volunteers received 3-T REACT MRA, acquired threefold: (i) CS acceleration factor 7 (CS7), scan time 1:20 min:s; (ii) CS acceleration factor 10 (CS10), scan time 0:55 min:s; and (iii) CS-AI acceleration factor 10 (CS10-AI), scan time 0:55 min:s. Two radiologists rated the image quality of seven arterial segments and overall image noise. Additionally, a pairwise forced-choice comparison was conducted. Apparent signal-to-noise ratio (aSNR) and contrast-to-noise ratio (aCNR) were measured, and image sharpness was assessed using the edge-rise distance (ERD). Multiple t-tests and nonparametric tests with Bonferroni correction were performed for comparison to CS7 as the reference standard.
resultsCompared to CS7, CS10 showed lower image quality (p < 0.001) while CS10-AI obtained higher scores (p = 0.010). Image noise was similar between CS7 and CS10 (p = 0.138) while CS10-AI yielded a lower noise (p = 0.008). Forced choice revealed preferences for CS7 over CS10 (p < 0.001), but no preference between CS7 and CS10-AI (p > 0.999). Compared to CS7, aSNR and aCNR were lower in CS10 (p < 0.001) and the ERD was longer (p = 0.004), while CS10-AI provided better aSNR and aCNR (p = 0.001) and showed no difference in ERD (p = 0.776).
conclusionSub-1-min CS-AI cervical REACT MRA was acquired without compromising image quality. RELEVANCE STATEMENT: The implementation of a fast and reliable non-contrast MRA has the potential to reduce costs and time while increasing patient comfort and safety. Clinical studies evaluating the diagnostic performance for stenosis or dissection are needed.
trial registrationDRKS00030210 (German Clinical Trials Register; https://drks.de/ ) KEY POINTS: Deep learning reconstruction enables sub-1-min non-contrast-enhanced MRA of extracranial arteries. Acceleration without deep learning reconstruction causes inferior image quality. Acceleration with deep learning reconstruction exceeds, in part, the clinical standard.
Indexed as