Evidence map›Paper›PMID 39966071›Full record

ArticleBrachytherapy

3D-printed template design to improve

Kaitlyn Calabresi, Jacqueline Emrich, Sara Belko, Robert Pugliese, Lydia Komarnicky-Kocher, Firas Mourtada

Abstract read
In one paragraph

Article in Brachytherapy. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kaitlyn CalabresiDepartment of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA 19107.
Jacqueline EmrichDepartment of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA 19107; Wills Eye Hospital, Philadelphia, PA 19107.
Sara BelkoSidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA 19107; Health Design Lab, Thomas Jefferson University, Philadelphia, PA 19107.
Robert PuglieseHealth Design Lab, Thomas Jefferson University, Philadelphia, PA 19107.
Lydia Komarnicky-KocherDepartment of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA 19107.
Firas MourtadaDepartment of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA 19107. Electronic address: firas.mourtada@jefferson.edu.

Funding

X-Ray Crystallography and Macromolecular CharacterizationP30CA056036 · NCI · THOMAS JEFFERSON UNIVERSITY · PI CHRISTINE M. EISCHEN · 1995 to 2026
$94.8M
NCI NIH HHS P30 CA056036
6 · The paper itself

Abstract

purposeTo demonstrate the utility of a QA program for seed localization, and to design a 3D-printed template to improve the accuracy of seed placement on custom-built METHODS AND MATERIALS: A seed localization analysis tool (SLAT) was developed in MATLAB to detect variations in seed placement relative to a treatment plan. A flexible seed placement template (3D-FSPT) was designed in CAD and printed using a Formlabs Form-3 3D printer. The 3D-FSPT and SLAT were tested using 3D-printed model eye plaques with nonradioactive seeds arranged following clinically-relevant treatment plans. Five clinical plaques were also evaluated.

resultsSLAT detected submillimeter scale variations in seed position with 2.3% error relative to the plan's seed coordinates, and with an uncertainty of ± 0.01 mm. The average seed displacement on the model plaques with free-handed seed placement was 1.31 mm (SD = 0.61), and the average seed orientation difference was 5.27 degrees (SD = 4.77). The average seed displacement on the clinical plaques was 0.77 mm (SD = 0.42), and the average seed orientation difference was 4.41 degrees (SD = 3.00). For the clinical plaques, changes in dosimetry to the tumor apex and critical eye structures were within acceptable tolerances. Seed displacement (mm) (p < 0.001) and seed orientation differences (degrees) (p = 0.008) were significantly lower using the template to guide seed placement on the model plaques compared to free-handed seed placement.

conclusionsThe feasibility of a 3D-FSPT and SLAT is demonstrated for improving seed placement accuracy relative to a treatment plan.

Indexed as

BrachytherapyIodine RadioisotopesPrinting, Three-DimensionalUveal NeoplasmsHumansRadiotherapy DosageRadiotherapy Planning, Computer-AssistedIodine-125Iodine Radioisotopes3D-printingEye plaque brachytherapyQuality assuranceRetinoblastomaUveal melanoma

Identifiers

PMID39966071
PMCPMC13527780

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.