Evidence map›Paper›PMID 39962748›Full record

ArticleJournal of applied clinical medical physics2025

Evaluation of OPTOS wide-field fundus image projections for radiotherapy planning of uveal melanoma.

Jörg Wulff, Benjamin Koska, Michael Giese, Christian Bäumer, Ronald Richter, Andreas Foerster, Nikolaos E Bechrakis, Beate Timmermann

Abstract readEvaluation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jörg WulffWest German Proton Therapy Centre Essen (WPE), Essen, Germany.ORCID https://orcid.org/0000-0001-8260-3523
Benjamin KoskaWest German Proton Therapy Centre Essen (WPE), Essen, Germany.
Michael GieseCoCreation Lab Produktinnovationen (CCLP), University Duisburg-Essen, Essen, Germany.
Christian BäumerWest German Proton Therapy Centre Essen (WPE), Essen, Germany.
Ronald RichterWest German Proton Therapy Centre Essen (WPE), Essen, Germany.
Andreas FoersterUniversity Hospital Essen, Essen, Germany.
Nikolaos E BechrakisUniversity Hospital Essen, Essen, Germany.
Beate TimmermannWest German Proton Therapy Centre Essen (WPE), Essen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo investigate the relationship between the stereographic and azimuthal equidistant projection (AEP) of the human retina for radiotherapy planning with OPTOS optomap wide-field fundus images (Optos, UK). Further, the geometric accuracy of an OPTOS fundus image is quantified.

methodsThe fundamental relationship between both projection modes was applied to transform images acquired with an OPTOS Silverstone camera to the azimuthal equidistant projection using MATLAB. Fundus images of four patients were used to quantitatively demonstrate the impact for neglecting the proper projection. For that purpose, a delineated contour for each patient was analyzed if created in a treatment planning system, which assumes AEP, and compared with an OPTOS image. Furthermore, an eye model with a novel 3D printed retina pattern was used to quantify the geometric accuracy for an OPTOS optomap image.

resultsThe difference between both projections was found substantial, leading to a change in delineated contours of more than 5 mm in the investigated cases and a change of delineated area of more than 40%. The geometric accuracy of OPTOS images of a customized eye model was found to be 0.2 mm on average, increasing to at most ∼0.5 mm at eye angles of 81°.

conclusionThe fundamental difference in the representation of the eye fundus needs to be accounted for in radiotherapy planning of uveal melanoma. The basic underlying relationship for transformation is known, but more research is required to quantify other aberrations. The novel use of 3D printed retina patterns with known dimensions is providing a flexible approach for further investigations.

Indexed as

Fundus OculiImage Processing, Computer-AssistedMelanomaRadiotherapy Planning, Computer-AssistedUveal NeoplasmsHumansRadiotherapy DosageRadiotherapy, Intensity-ModulatedRetinaUveal Melanoma3D printingFundus imagingproton therapy

Identifiers

PMID39962748
PMCPMC11969099

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.