ArticleKnee surgery & related research2025
Caliper verification and gap measurements of kinematic alignment total knee arthroplasty utilizing an imageless, accelerometer-based navigation system.
Article in Knee surgery & related research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeKinematic alignment (KA) in total knee arthroplasty (TKA) aims to restore the patient's knee to the prearthritic state. The purpose of this study was to investigate the accuracy of using an implant-agnostic, imageless, accelerometer-based navigation system to perform KA TKA on the basis of caliper verification and quantification of the flexion and extension gaps. MATERIALS AND
methodsSeven cadaveric lower extremities underwent primary TKA utilizing a kinematic alignment workflow with the imageless navigation system. Accuracy of the technique was confirmed through caliper verification of bone cuts.
resultsAll cuts were within 1 mm of anticipated measurements, except for the lateral tibial fragment, which averaged 1 mm (standard deviation [SD] 0.9 mm) thicker than anticipated. In extension, medial and lateral gaps were symmetric and averaged within 0.6 mm of expectation. In flexion, the medial gap averaged within 0.5 mm of expectation, while the lateral gap averaged 2.6 mm larger than the symmetric expectation, consistently producing a trapezoidal space.
conclusionsThe implementation of an accelerometer-based navigation system in KA TKA allows for highly accurate results, which was confirmed with caliper verification. This workflow produced a symmetric extension gap and a trapezoidal flexion gap with an average increased lateral flexion gap of 2.6 mm compared with the medial side.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.