Evidence map›Paper›PMID 39962170›Full record

ArticleScientific reports2025

Frequency stability improvement in EV-integrated power systems using optimized fuzzy-sliding mode control and real-time validation.

Benazeer Begum, Narendra Kumar Jena, Binod Kumar Sahu, Mohit Bajaj, Vojtech Blazek, Lukas Prokop

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Benazeer BegumDepartment of Electrical Engineering, ITER, Siksha 'O' Anusandhan Deemed to Be University, Bhubaneswar, Odisha, India.
Narendra Kumar JenaDepartment of Electrical Engineering, ITER, Siksha 'O' Anusandhan Deemed to Be University, Bhubaneswar, Odisha, India.
Binod Kumar SahuDepartment of Electrical Engineering, ITER, Siksha 'O' Anusandhan Deemed to Be University, Bhubaneswar, Odisha, India. binoditer@gmail.com.
Mohit BajajDepartment of Electrical Engineering, Graphic Era (Deemed to be University), Dehradun, 248002, India. mohitbajaj.ee@geu.ac.in.
Vojtech BlazekENET Centre, CEET, VSB-Technical University of Ostrava, 708 00, Ostrava, Czech Republic.
Lukas ProkopENET Centre, CEET, VSB-Technical University of Ostrava, 708 00, Ostrava, Czech Republic.

Funding

Ministry of Education, Youth and Sports TN02000025 National Centre for Energy IIMinistry of the Environment of the Czech Republic CZ.10.03.01/00/22_003/0000048
6 · The paper itself

Abstract

The rapid growth in power demand, integration of renewable energy sources (RES), and intermittent uncertainties have significantly challenged the stability and reliability of interconnected power systems. The integration of electric vehicles (EVs), with their bidirectional power flow, further exacerbates the frequency fluctuation in the power system. So, to mitigate the frequency & power deviations as well as to stabilize the power system integrated with distributed generators (DGs) and EVs, robust & intelligent control strategies are indispensable. This study dedicates a novel Fuzzy-Sliding Mode Controller (FSMC) utilized for load frequency control (LFC). First, the dynamic response has been evaluated by using a Sliding Mode Controller (SMC), showcasing its robustness against external disturbances and parameter uncertainties. Second, to enhance the performance, fuzzy logic is integrated with SMC, leveraging its adaptability to create the FSMC controller. This FSMC has achieved the superiority by handling non-linearities, communication delays and parameter variations in the system. A significant contribution like the design and tuning of the controllers using a Modified Gannet Optimization Algorithm (MGOA) has been established. The potential of MGOA over GOA has been corroborated by convergence speed and precision through benchmark functions. Furthermore, the paper extensively analyzes the impact of EV integration to the frequency and tie-line power dynamics under varying regulation capacities and uncertain operating conditions. Comparative studies demonstrate that the MGOA-tuned FSMC achieves faster settling times, reduced overshoot, and improved stability metrics compared to conventional and state-of-the-art methods. Finally, the MATLAB-based simulation results are validated through real-time implementation on the OPAL-RT 4510 platform, confirming the robustness and practicality of the proposed methodology in addressing modern power system challenges involving high renewable penetration and EV integration.

Indexed as

Electric vehicles integrationFrequency stabilityFuzzy-sliding mode controllerGannet Optimization AlgorithmLoad frequency controlModified Gannet OptimizationReal-time simulationSliding mode controller

Identifiers

PMID39962170
PMCPMC11832784

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.