ArticlePediatric radiology2025
Two-year experience of radiation dose watch for pediatric general fluoroscopic examinations.
Article in Pediatric radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe radiation dose of pediatric general fluoroscopy exams has historically been a topic of concern, with ongoing efforts and significant progress made.
objectiveThe purpose of this study is to evaluate dose performance with a dose monitor program for pediatric general fluoroscopy. MATERIALS AND
methodsPediatric general fluoroscopy exams performed between April 1, 2020, and Dec. 31, 2022 were collected and monitored. For each exam, fluoroscopy time, dose-area-product (DAP), reference air kerma (RAK), and patient demographic information were analyzed. RAK, DAP, and fluoroscopy time were tested using Pearson's correlation methods for the three most frequently performed procedures. The influence of patient habitus on dose was studied using linear regression methods. Dose performance among radiologists was compared and so the Wilcoxon signed-rank test between radiologists with ≤ 5 years and > 5 years of experience post fellowship. A significance level of P<0.05 was used to determine statistical significance.
resultsA total of 12,029 cases were analyzed and the median RAK values range from 0.10 mGy to 1.30 mGy. RAK demonstrated a stronger correlation with DAP (upper gastrointestinal (UGI), R=0.97; P<0.0001) than with fluoroscopy time (UGI, R=0.19; P<0.0001). RAK values were linearly correlated with patient weight (UGI, R=0.49; P<0.0001). A stable trend of median RAK values was observed across the studied time periods. Radiologists with ≤ 5 years' experience showed significantly lower (P<0.0001) RAK than those with > 5 years' experience.
conclusionVariations of pediatric general fluoroscopy dose performance were observed when comparing with other investigations. This study demonstrated that both patient size and operator experience influence radiation output in general fluoroscopy, factors that should be considered for pediatric fluoroscopy procedures.