Evidence map›Paper›PMID 39960416›Full record

ArticleACS sensors2025

Using Machine Learning and Optical Microscopy Image Analysis of Immunosensors Made on Plasmonic Substrates: Application to Detect the SARS-CoV-2 Virus.

Pedro R A Oiticica, Monara K S C Angelim, Juliana C Soares, Andrey C Soares, José L Proença-Módena, Odemir M Bruno, Osvaldo N Oliveira

Abstract read
In one paragraph

Article in ACS sensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Conundrums of Localized Surface Plasmon Resonance Biosensors.Small (Weinheim an der Bergstrasse, Germany) · 2026
    Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Pedro R A OiticicaSão Carlos Institute of Physics (IFSC), University of São Paulo (USP), São Carlos, SP 13566-590, Brazil.ORCID 0000-0002-1658-9572
Monara K S C AngelimDepartment of Genetics, Evolution, Microbiology and Immunology, Institute of Biology, University of Campinas, Campinas, SP 13083-862, Brazil.ORCID 0000-0001-6235-956X
Juliana C SoaresSão Carlos Institute of Physics (IFSC), University of São Paulo (USP), São Carlos, SP 13566-590, Brazil.ORCID 0000-0001-5455-1770
Andrey C SoaresNanotechnology National Laboratory for Agriculture (LNNA), Embrapa Instrumentação, São Carlos, SP 13560-970, Brazil.ORCID 0000-0003-4601-3555
José L Proença-MódenaDepartment of Genetics, Evolution, Microbiology and Immunology, Institute of Biology, University of Campinas, Campinas, SP 13083-862, Brazil.ORCID 0000-0002-4996-3153
Odemir M BrunoSão Carlos Institute of Physics (IFSC), University of São Paulo (USP), São Carlos, SP 13566-590, Brazil.ORCID 0000-0002-2945-1556
Osvaldo N OliveiraSão Carlos Institute of Physics (IFSC), University of São Paulo (USP), São Carlos, SP 13566-590, Brazil.ORCID 0000-0002-5399-5860

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this article, we introduce a diagnostic platform comprising an optical microscopy image analysis system coupled with machine learning. Its efficacy is demonstrated in detecting SARS-CoV-2 virus particles at concentrations as low as 1 PFU (plaque-forming unit) per milliliter by processing images from an immunosensor on a plasmonic substrate. This high performance was achieved by classifying images with the support vector machine (SVM) algorithm and the MobileNetV3_small convolutional neural network (CNN) model, which attained an accuracy of 91.6% and a specificity denoted by an F1 score of 96.9% for the negative class. Notably, this approach enabled the detection of SARS-CoV-2 concentrations 1000 times lower than the limit of detection achieved with localized surface plasmon resonance (LSPR) sensing using the same immunosensors. It is also significant that a binary classification between control and positive classes using the MobileNetV3_small model and the random forest algorithm achieved an accuracy of 96.5% for SARS-CoV-2 concentrations down to 1 PFU/mL. At such low concentrations, straightforward screening of newly infected patients may be feasible. In supporting experiments, we verified that texture was the main contributor to the distinguishability of images taken at different SARS-CoV-2 concentrations, indicating that the combination of ML and image analysis may be applied to any biosensor whose detection mechanism is based on adsorption.

Indexed as

Biosensing TechniquesCOVID-19Image Processing, Computer-AssistedMachine LearningMicroscopySARS-CoV-2HumansImmunoassayNeural Networks, ComputerSupport Vector MachineSurface Plasmon Resonancecomputer visionimmunosensormachine learningplasmonic substratesSARS-CoV-2 virus

Identifiers

PMID39960416
PMCPMC11877505

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.