Evidence map›Paper›PMID 39959482›Full record

ArticleHeliyon2025

Impact of immobilization system angle, body mass index and breast size on breast radiotherapy accuracy using EPID-only setup.

Ioana-Claudia Costin, Loredana G Marcu

Registry-linked trialAbstract read
In one paragraph

Article in Heliyon, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07676032 (The Impact of Body Composition on Setup Errors in Patients Undergoing Radiotherapy With Thermoplastic Mask Immobilization), which is not on this map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07676032 not yet recruitingnot on this mapstarted 2026, after this paper: background citation

The Impact of Body Composition on Setup Errors in Patients Undergoing Radiotherapy With Thermoplastic Mask Immobilization: A Single-Center Prospective Cohort Study

Typeobservational_patient_registrySponsorShijiazhuang People's HospitalRan2026 to 2027Enrolled150ConditionsMalignant Neoplasms
3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ioana-Claudia CostinWest University of Timisoara, Faculty of Physics, 300223, Timisoara, Romania.
Loredana G MarcuFaculty of Informatics & Science, University of Oradea, Oradea, 410087, Romania.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aims to assess setup errors for patients immobilized on different board inclinations and to evaluate the effect of body mass index (BMI) and breast size on positioning errors. Furthermore, the dosimetric impact of setup errors on target and organs at risk was measured using three different irradiation techniques (3D conformal radiotherapy, intensity modulated and volumetric modulated arc radiotherapy). A cohort of 40 breast cancer patients was split into two groups as a function of immobilization board inclination: 20 patients immobilized on 7.5° inclination (group A) and 20 on 0° (group B). Systematic and random errors were determined with weekly portal and tangential images. A strong correlation between BMI and both systematic (r = 0.720) and random errors (r = 0.752) was observed in posterior direction for group B, while the correlation between breast size and setup errors showed a moderate association under systematic errors for right (r = -0.507) and left (r = 0.503) directions. The dosimetric impact of setup errors on target volume showed higher contribution from systematic than from random errors. Suboptimal coverage of target volume was more prominent in group A for all planning techniques (46.65Gy 3DCRT, 46.95Gy IMRT, 46.90Gy VMAT). Patients with high BMI could benefit from the inclined immobilization board with a higher frequency of image position verification. When comparing 3DCRT versus modulated techniques the ipsilateral lung is better spared with the latter, while the contralateral lung is more efficiently protected with conformal technique.

Indexed as

Breast cancerIMRTPatient setupRandom errorSystematic errorVMAT

Identifiers

PMID39959482
PMCPMC11830291

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.