Evidence map›Paper›PMID 39958248›Full record

ArticleJournal of clinical and experimental dentistry2025

Influence of indirect air-cooling on the variation in intrapulpal temperature during rapid high-intensity light-curing using a bulk-fill resin composite.

Samille Biasi Miranda, Vinícius Cristovão de Oliveira Mendes, Caroline de Farias Charamba Leal, Luiz Antonio Soares Falson, Guilherme da Luz Silva, Ana Karina Maciel de Andrade, Rodrigo Barros Esteves Lins, Marcos Antônio Japiassú Resende Montes

Abstract read
In one paragraph

Article in Journal of clinical and experimental dentistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Samille Biasi MirandaDepartament of Restorative Dentistry, School of Dentistry, University of Pernambuco, Recife 50100-130, PE, Brazil.
Vinícius Cristovão de Oliveira MendesDepartament of Restorative Dentistry, School of Dentistry, University of Pernambuco, Recife 50100-130, PE, Brazil.
Caroline de Farias Charamba LealDepartament of Restorative Dentistry, School of Dentistry, University of Pernambuco, Recife 50100-130, PE, Brazil.
Luiz Antonio Soares FalsonDepartment of Semiology and Clinical, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil.
Guilherme da Luz SilvaDepartment of Oral Medicine, School of Dentistry, Postgraduate Program in Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil.
Ana Karina Maciel de AndradeDepartment of Restorative Dentistry, School of Dentistry, Federal University of Paraíba, João Pessoa 58051-900, PB, Brazil.
Rodrigo Barros Esteves LinsDepartment of Restorative Dentistry, School of Dentistry, Federal University of Alagoas, Maceió 57072-900, AL, Brazil.
Marcos Antônio Japiassú Resende MontesDepartment of Dental Materials, School of Dentistry, University of Pernambuco, Recife, PE, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: This study investigated the effect of indirect air-cooling on the variation in intrapulpal temperature (ΔT) during different light-curing protocols of bulk-fill resin composites in molars with class V cavities. Material and Methods: A nonretentive class V cavity was prepared in a maxillary molar. The intrapulpal temperature changes with and without indirect air-cooling were recorded using a type K thermocouple. The cavity was restored with bulk-fill resin composites: Tetric PowerFlow (Ivoclar, Vivadent) and Filtek Bulk-Fill Flow (3 M, ESPE). The tooth was exposed to different light-curing protocols (n=5) using the Valo Grand light-curing unit: (i) high-intensity light-curing protocol of 3200 mW/cm² (3 and 6 s) and (ii) moderate-intensity light-curing protocol of 1000 mW/cm² (10 and 20 s). The ΔT data were subjected to two-way ANOVA, followed by the Bonferroni post hoc test. Results: A significant increase in temperature was observed with the use of the high-intensity light-curing resin composite without indirect air-cooling. In addition, the application of air-cooling significantly decreased the temperature in all the groups except for the Tetric PowerFlow bulk-fill resin composite at 3 s of light-curing. Conclusions: Indirect air-cooling resulted in a lower increase in intrapulpal temperature during the light-curing of bulk-fill resin composites, making it an effective alternative technique for controlling the temperature rise in class V restorations with 1 mm of remaining dentin.

Identifiers

PMID39958248
PMCPMC11829722

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.