Evidence map›Paper›PMID 39958032›Full record

ArticleCureus2025

Safety and Cost-Effectiveness of the FAM-DX Three-Dimensional CARTO Navigation System in Zero Fluoroscopy Electrophysiology Studies for Supraventricular Tachycardia: A Retrospective Cohort Study.

Shaden Daloub, Abdusalam Elgrewi, Tala Altarawneh, Jay C Jensen, Mamdouh Y Souleymane, Khalid Abozguia

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Shaden DaloubAdvanced Heart Failure and Heart Transplant, Kansas City University, Kansas City, USA.
Abdusalam ElgrewiInternal Medicine, Marshall Health, Huntington, USA.
Tala AltarawnehInternal Medicine, Marshall University Joan C. Edwards School of Medicine, Huntington, USA.
Jay C JensenInternal Medicine, Marshall University Joan C. Edwards School of Medicine, Huntington, USA.
Mamdouh Y SouleymaneInternal Medicine, Marshall University Joan C. Edwards School of Medicine, Huntington, USA.
Khalid AbozguiaElectrophysiology, Marshall University Joan C. Edwards School of Medicine, Huntington, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background The zero fluoroscopy (ZF) ablation technique reduces radiation exposure for both medical staff and patients but typically requires specialized navigation ablation catheters. The innovative FAM-DX Three-Dimensional CARTO Navigation System enables 3D mapping without the need for these specialized catheters. This study investigates the safety, feasibility, efficacy, and cost-effectiveness of using the FAM-DX system for ZF electrophysiology (EP) studies in patients with supraventricular tachycardia (SVT). Methods A retrospective analysis was performed at a single center on patients who underwent EP studies using the FAM-DX system between November 2021 and December 2023. Exclusion criteria included patients under 18, pregnant women, those with recent pacemaker implantation, and individuals requiring specific ablations. Clinical data, including patient characteristics, indications, procedure details, fluoroscopy use, ablation requirements, and any procedure-related adverse events, were collected. Results A total of 87 consecutive patients (mean age: 53 ± 18.9 years) were included in this retrospective cohort analysis. Of these, 86 patients (98.85%) successfully underwent ZF ablation using the FAM-DX 3D navigation system, with mapping conducted in various heart regions, including the right atrium, His bundle, coronary sinus, superior vena cava, and inferior vena cava. Only one patient required fluoroscopy due to vascular access issues. Notably, in 41% of cases (36 patients), the ablation catheter was not initially needed or used during the electrophysiological study, suggesting a potential cost-saving benefit given the catheter's cost of approximately $2,431. Conclusions Our study demonstrates that the FAM-DX system enables safe and efficient 3D mapping and ZF techniques for SVT EP studies. This cost-effective approach suggests that the use of ablation catheters may be unnecessary for certain patients. Further research is required to validate the broader adoption of ZF techniques and their application in more complex left-sided procedures.

Indexed as

carto navigation systemelectrophysiology studiesfam dxsvt ablationzero fluoroscop

Identifiers

PMID39958032
PMCPMC11826955

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.