Evidence map›Paper›PMID 39955657›Full record

ArticleJournal of applied clinical medical physics2025

Commissioning of a motion management system for a 1.5T Elekta Unity MR-Linac: A single institution experience.

Blake R Smith, Joel St-Aubin, Daniel E Hyer

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Characterizing the motion management system accuracy on a 1.5T MR-Linac.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2025
    Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Blake R SmithDepartment of Radiation Oncology, University of Iowa, Iowa City, Iowa, USA.ORCID https://orcid.org/0009-0000-0117-2590
Joel St-AubinDepartment of Radiation Oncology, University of Iowa, Iowa City, Iowa, USA.ORCID https://orcid.org/0000-0001-9356-8567
Daniel E HyerDepartment of Radiation Oncology, University of Iowa, Iowa City, Iowa, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis work describes a single institution experience of commissioning a real-time target tracking and beam control system, known as comprehensive motion management, for a 1.5 T Elekta MR-Linac.

methodsAnatomical tracking and radiation beam control were tested using the MRI

resultsIt was determined that APM correctly predicted the 3D position of a dynamically moving tracking target to within 1.5 mm for 95% of the imaging frames with no deviation exceeding 2 mm. Among the breathing traces investigated, the mean latency ranged between -21.7 and 7.9 ms with 95% of all observed latencies within 188.3 ms. No discernable differences were observed in the relative profiles or cumulative output for a gated beam relative to an ungated beam with minimal dosimetric impact observed due to system latency. Measured dose profiles for all gated scenarios retained a gamma pass rate of 97% or higher for a 3%/2 mm criteria relative to a theoretical gated dose profile without latency or tracking inaccuracies.

conclusionMRI-guided target tracking and automated beam delivery control were successfully commissioned for the Elekta Unity MR-Linac. These gating features were shown to be highly accurate with an effectively small beam latency for a range of regular and irregular respiratory breathing traces.

Indexed as

Magnetic Resonance ImagingParticle AcceleratorsPhantoms, ImagingQuality Assurance, Health CareRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedRespiratory-Gated Imaging TechniquesHumansImage Processing, Computer-AssistedMotionMovementRadiotherapy DosageRadiotherapy, Intensity-ModulatedRespirationcommissioninggatingmotion managementMR‐Linacunity

Identifiers

PMID39955657
PMCPMC11969090

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.