Screening dental implant design parameters for effect on the fatigue limit of reduced-diameter implants.

Megha Satpathy, Matthew Loeb, Rose M Jose, Matthew J Sinclair, Yuanyuan Duan, Susana M Salazar Marocho, Michael D Roach, Jason A Griggs

Abstract read
In one paragraph

Article in Dental materials : official publication of the Academy of Dental Materials, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Megha SatpathyDepartment of Biomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Room D528, Jackson, MS 39216-4505, USA.
Matthew LoebUniversity Oral and Facial Surgery, 651 Helen Keller Boulevard, Tuscaloosa, AL 35404, USA.
Rose M JoseDepartment of Biomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Room D528, Jackson, MS 39216-4505, USA.
Matthew J SinclairDepartment of Biomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Room D528, Jackson, MS 39216-4505, USA.
Yuanyuan DuanDepartment of Biomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Room D528, Jackson, MS 39216-4505, USA.
Susana M Salazar MarochoDepartment of Biomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Room D528, Jackson, MS 39216-4505, USA.
Michael D RoachDepartment of Biomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Room D528, Jackson, MS 39216-4505, USA.
Jason A GriggsDepartment of Biomedical Materials Science, University of Mississippi Medical Center, 2500 North State Street, Room D528, Jackson, MS 39216-4505, USA. Electronic address: jgriggs@umc.edu.

Funding

Design Optimization of Reduced-Diameter Implants in Simulated and Cadaver BoneR01DE026144 · NIDCR · UNIVERSITY OF MISSISSIPPI MED CTR · PI GRIGGS, JASON A · 2019 to 2023
$1.8M
NIDCR NIH HHS R01 DE026144
6 · The paper itself

Abstract

objectivesThis study screened the design parameters of a reduced-diameter implant to determine which parameters have the most significant effect on the implant fatigue limit.

methodsA dental implant assembly, which included an implant body (Biomet 3i), an abutment (GingiHue®), and an abutment screw (Gold-Tite Square screw) was scanned using micro-computed tomography (SkyScan 1172) and was measured using Mimics (Materialise) and an optical microscope (VHX-1000, Keyence). Sixteen design parameters were measured, and the values of the commercial design were taken as reference level for each design parameter. Values up to 20 % lower and 20 % higher than the reference were explored using a Taguchi orthogonal array (DOE++, Reliasoft), which varies more than one design parameter at a time to efficiently explore all main effects and lower order interactions across few implant designs. Solid models of these 27 implant designs and the reference design were constructed using SOLIDWORKS (Dassault Systèmes). Each solid model was loaded according to ISO 14801. fe-safe (Dassault Systèmes) was used to estimate the fatigue limits. ANOVA statistical test in DOE++ was used to screen the design parameters.

resultsInteraction between the coronal and apical tapers of the implant body had a significant effect on the fatigue limit (p ≤ 0.05), where fatigue limit was low for designs with a constant taper. Conversely, the combination of high degree of apical taper and low degree of coronal taper lead to the highest fatigue limit. SIGNIFICANCE: Using a Taguchi orthogonal array proved to be an efficient strategy for screening implant design parameters for effect on fatigue limit. The modified implant designed by manipulating the most influential parameters is predicted to have much greater fatigue limit compared to the commercially available design.

Indexed as

Dental ImplantsDental Prosthesis DesignDental Restoration FailureDental Stress AnalysisDental AbutmentsDental Implant-Abutment DesignHumansMaterials TestingX-Ray MicrotomographyDental ImplantsDental implantsFatigue fractureFinite element methodTaguchi orthogonal arrays

Identifiers

PMID39955169
PMCPMC13472671

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.