Evidence map›Paper›PMID 39954303›Full record

ArticleJournal of the mechanical behavior of biomedical materials2025

Risk of bony endplate failure during vertebral fracture.

Neilesh R Frings, Elise F Morgan

Abstract read
In one paragraph

Article in Journal of the mechanical behavior of biomedical materials, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Neilesh R FringsBoston University Department of Biomedical Engineering, 44 Cummington Mall Room 403, Boston, MA, 02215, USA; Boston University Center for Multiscale and Translational Mechanobiology, 44 Cummington Mall Room 345, Boston, MA, 02215, USA. Electronic address: nfrings@bu.edu.
Elise F MorganBoston University Department of Biomedical Engineering, 44 Cummington Mall Room 403, Boston, MA, 02215, USA; Boston University Department of Mechanical Engineering, 110 Cummington Mall Room 101, Boston, MA, 02215, USA; Boston University Center for Multiscale and Translational Mechanobiology, 44 Cummington Mall Room 345, Boston, MA, 02215, USA. Electronic address: efmorgan@bu.edu.

Funding

3-D Visualization and Prediction of Vertebral FracturesR01AR054620 · NIAMS · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI MORGAN, ELISE F · 2008 to 2025
$6.7M
3-D Visualization and Prediction of Vertebral FracturesR56AR054620 · NIAMS · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI MORGAN, ELISE F · 2013 to 2013
$364k
NIAMS NIH HHS R01 AR054620NIAMS NIH HHS R56 AR054620
6 · The paper itself

Abstract

The endplate region of the vertebra, which includes the bony endplate (BEP) and underlying subchondral trabecular bone (STB), is critically involved in vertebral fracture (VF). While evidence abounds that failure initiates in the endplate region, the relative risk of failure of the BEP vs. STB has not been established. In this study, micro-finite element models were constructed of L1 vertebrae (n = 21) that were mechanically tested in a prior study and given experimentally matched boundary conditions corresponding to the vertebra's yield point. Volumes of interest (VOIs) were defined corresponding to the BEP and STB; the remainder was defined as the mid-vertebral body (MVB). The proportion of elements within each VOI that yielded was defined as the VOI yield fraction, and this value divided by the yield fraction of the entire model was defined as the normalized yield fraction. While yield fraction did not differ across VOIs (p = 0.179), normalized yield fraction was greater in the BEP than STB and MVB (p < 0.001), indicating a higher risk of yield in the BEP compared to the other two VOIs. None of the yield fractions was correlated with BEP or STB microstructure, and tension (rather than compression) was the dominant mode of tissue level yield. These findings indicate that the BEP, more so than the STB, is likely the site of VF initiation and that current methods of screening for VF risk, because they omit specific analysis of the BEP, are missing the region that matters the most. The endplate region of the vertebra, which includes the bony endplate (BEP) and underlying subchondral bone (SB), is critically involved in vertebral fracture (VF). While evidence abounds that failure initiates in the endplate region, the relative risk of failure of the BEP vs. SB has not been established. In this study, micro-finite element models were constructed of L1 vertebrae (n = 21) that had been mechanically tested in a prior study, and they were given experimentally matched boundary conditions corresponding to the vertebra's yield point. Volumes of interest (VOIs) were defined corresponding to the BEP and SB; the remainder was defined as the mid-vertebral body (MVB). The proportion of yielded elements within each VOI was defined as the VOI yield fraction, and this value divided by the yield fraction of the entire model was defined as the normalized yield fraction. While yield fraction did not differ across VOIs (p = 0.179), normalized yield fraction was greater in the BEP than SB and MVB (p < 0.001), indicating a higher risk of yield in the BEP compared to the other two VOIs. None of the yield fractions was correlated with BEP or SB microstructure, and tension (rather than compression) was the dominant mode of tissue level yield. These findings indicate that the BEP, more so than the SB, is likely the site of VF initiation and that current methods of screening for VF risk, because they omit specific analysis of the BEP, are missing the region that matters the most.

Indexed as

Lumbar VertebraeMechanical PhenomenaSpinal FracturesBiomechanical PhenomenaFinite Element AnalysisHumansRiskStress, Mechanical

Identifiers

PMID39954303
PMCPMC12227123

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.