ArticleScience advances2025
High-performance electroadhesive clutches with multilayered architecture.
Article in Science advances, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Electroadhesion Suction Cups.Advanced materials (Deerfield Beach, Fla.) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Electroadhesive (EA) clutches are promising for advanced motion and force control in robotics, haptics, and rehabilitation, owing to their compactness and light weight. However, their practical use is limited by the inability to deliver high forces at low voltages, primarily due to a lack of understanding of their mechanics. We introduce a novel deformable body fracture mechanics approach and high-resolution strain field imaging to reveal that nonuniform stress distributions cause EA clutches to fail through delamination and crack propagation. Using this insight, we developed EA clutches sustaining 22 newtons over 1 square centimeter at 100 volts, achieving the highest stress per voltage among similar clutches. This was achieved by incorporating a soft interlayer and peeling stopper for uniform stress distribution and mitigating the failure modes. These EA clutches were integrated into a lightweight ring-based wearable system for finger rehabilitation and haptics. Our findings lay the groundwork for designing low-voltage, high-performance EA clutches for next-generation motion and force control applications.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.