Mechanical Compatibility in Stitch Configuration and Sensor Adhesion for High-Fidelity Pulse Wave Monitoring.

Zhongda Chen, Jun Song, Yu Lu, Jing Zhu, Hongxu Zhu, Wenxian Du, Benhui Hu

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zhongda ChenSchool of Biomedical Engineering and Informatics, Nanjing Medical University, 101 Longmian Avenue, Nanjing, 211166, China.ORCID https://orcid.org/0000-0003-0518-7938
Jun SongMaterdicine Lab, School of Life Sciences, Shanghai University, 99 Shangda Road, Shanghai, 200444, China.ORCID https://orcid.org/0000-0002-7689-1722
Yu LuSchool of Mechanical Engineering, Nantong University, 9 Seyuan Road, Nantong, 226002, China.ORCID https://orcid.org/0000-0002-6742-4321
Jing ZhuDepartment of Geriatrics, Affiliated Nantong Hospital of Shanghai University (The Sixth People's Hospital of Nantong), Shanghai University, 500 Yonghe Road, Nantong, 226011, China.
Hongxu ZhuInstitute of Diagnostic and Interventional Radiology, Shanghai Sixth People's Hospital, School of Medicine, Shanghai Jiaotong University, 600 Yishan Road, Xuhui, Shanghai, 200233, China.
Wenxian DuInstitute of Diagnostic and Interventional Radiology, Shanghai Sixth People's Hospital, School of Medicine, Shanghai Jiaotong University, 600 Yishan Road, Xuhui, Shanghai, 200233, China.ORCID https://orcid.org/0009-0000-0917-0987
Benhui HuSchool of Biomedical Engineering and Informatics, Nanjing Medical University, 101 Longmian Avenue, Nanjing, 211166, China.ORCID https://orcid.org/0000-0002-7404-6525

Funding

Functional Materials Programme of Poly Plastic Masterbatch (Suzhou) Co., Ltd. 2023008Jiangsu Funding Program for Excellent Postdoctoral Talent 2023ZB469Nantong Xinquan Textile Technology Co., Ltd. 2024FK0546National Natural Science Foundation of China 32401157Shanghai Pujiang program 22PJD026
6 · The paper itself

Abstract

Wearable electronics can achieve high-fidelity monitoring of pulse waveforms on the body surface enabling early diagnosis of cardiovascular diseases (CVDs). Textile-based wearable devices offer advantages in terms of high permeability and comfort. However, knitted strain sensors struggle to capture small-range deformation signals due to stress dissipation during friction and slip of yarns within the textiles. They are optimized for mechanical adaptability and adhesive capability. In this work, the stitch configurations of knitted structure are adjusted to optimize the energy dissipation ratio during deformation and waveform fitting performance. These electric-mechanical results enabled the selection of the most suitable knitted structure for the clinical diagnosis. On the other hand, the sensor's adhesion is optimized with respect to electrical-force-strain coupling and energy transfer efficiency at the interface between skin and sensor. The balance between the storage modulus and loss modulus are adjusted via the crosslinking degree of the polyacrylamide (PAAm) hydrogel network. As a result, the optimized knitted sensor enables stable collection of pulse waveforms from the radial and dorsalis pedis arteries. In human patient evaluations, the knitting-based strain sensor can distinguish patients with different potential CVD risks through extracted characteristic indicators.

Indexed as

Cardiovascular DiseasesPulse Wave AnalysisWearable Electronic DevicesHumansMonitoring, PhysiologicTextilesknitted structurepolyacrylamide hydrogelpulse wavestrain sensor

Identifiers

PMID39951279
PMCPMC11984903

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.