Validation of real-time viewing distance and ambient illumination measurement with two wearable sensors.

Samrat Sarkar, Sieu K Khuu, Fuensanta A Vera-Diaz, Pauline Kang

Abstract readValidation Study
In one paragraph

Article in Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Guideline
  2. Validation of a Multimodal Wearable Device for Assessing Environmental and Behavioral Risk Factors of Myopia in Children and Adolescents.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
    Article
  3. Review
  4. Article
  5. Validation of real-time viewing distance and ambient illumination measurement with two wearable sensors.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Samrat SarkarSchool of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia.ORCID 0000-0003-0134-7498
Sieu K KhuuSchool of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia.ORCID 0000-0003-1850-0225
Fuensanta A Vera-DiazNew England College of Optometry, Boston, Massachusetts, USA.ORCID 0000-0001-8668-9707
Pauline KangSchool of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia.ORCID 0000-0002-3969-2871

Funding

Meta Platforms Technologies, LLCUNSW Sydney
6 · The paper itself

Abstract

purposeTo report the repeatability and accuracy of viewing distance and ambient illumination measured with the Vivior and Clouclip wearable sensors in a controlled laboratory setting and while young adults performed different near visual tasks.

methodsFor Study 1, viewing distance and ambient illumination were measured repeatedly for 2 days with two sensors mounted on a mannequin. Results were compared with standard measures (ruler, lux meter) using linear regression and Bland-Altman analysis. In Study 2, viewing distances were captured in 13 young adults while they performed four near tasks for 20 min each (reading a printed article, reading an article on an iPad, typing on a laptop or watching videos on an iPad) under three illuminations (500, 250 and 25 lux). Results were compared between the devices and with a standard ruler and differences tested statistically using ANOVA and Tukey's multiple comparison tests.

resultsIn Study 1, a positive linear relationship was observed between viewing distances measured by each sensor and the standard ruler (mean [SD] difference of -0.12 cm [0.23] for Vivior, -0.18 cm [0.51] for Clouclip), with good repeatability (mean [SD] difference between 2 days was 0.02 cm [0.24] for Vivior, -0.14 cm [0.35] for Clouclip). A positive linear relationship was also observed between illumination measured by each sensor and the luxmeter (mean [SD] difference of -16.85 lux [325.5] for Vivior, 39.12 lux [335.6] for Clouclip). In Study 2, the viewing distances during the four near tasks were not significantly different between the three methods used. Shorter working distances were measured with all methods when reading a printed article compared to typing on a laptop and watching a video on the iPad (all p < 0.05).

conclusionVivior and Clouclip are recommended for real-time capture of near vision duration, distance and light exposure in future studies aiming to understand the effect of habitual visual environment.

Indexed as

Distance PerceptionLightingWearable Electronic DevicesAdultEquipment DesignFemaleHumansMaleReproducibility of ResultsYoung Adultambient illuminationnear vision behaviourreal‐time viewing distancewearable sensors

Identifiers

PMID39950839
PMCPMC11976500

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.