Bone quality assessment around dental implants in cone-beam CT images: effect of rotation mode and metal artefact reduction tool.

Lauren Bohner, Hian Parize, João Victor Cunha Cordeiro, Natalia Koerich Laureano, Johannes Kleinheinz, Ricardo Armini Caldas, Dorothea Dagassan-Berndt

Abstract read
In one paragraph

Article in Dento maxillo facial radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Lauren BohnerDepartment of Cranio-Maxillofacial Surgery, University Hospital Muenster, Muenster, 48149, Germany.ORCID 0000-0003-3637-3928
Hian ParizeDepartment of Cranio-Maxillofacial Surgery, University Hospital Muenster, Muenster, 48149, Germany.ORCID 0000-0003-0205-5892
João Victor Cunha CordeiroDepartment of Dentistry, Federal University of Santa Catarina, Florianópolis, SC 88040-370, 88040370, Brazil.ORCID 0009-0009-9394-9787
Natalia Koerich LaureanoDepartment of Oral Pathology, Federal University of Rio Grande do Sul, Porto Alegre, 90650970, Brazil.ORCID 0000-0002-9587-2842
Johannes KleinheinzDepartment of Cranio-Maxillofacial Surgery, University Hospital Muenster, Muenster, 48149, Germany.ORCID 0000-0003-0012-6140
Ricardo Armini CaldasDepartment of Dentistry, Federal University of Santa Catarina, Florianópolis, SC 88040-370, 88040370, Brazil.ORCID 0000-0002-5362-4744
Dorothea Dagassan-BerndtCenter for Dental Imaging, University Center for Dental Medicine Basel UZB, University of Basel, Basel, 4058, Switzerland.ORCID 0000-0003-1109-8763

Funding

International Team for Implantology 2019_1425
6 · The paper itself

Abstract

objectivesThe purpose of this study was to evaluate how artefacts caused by titanium and zirconia dental implants affect the bone quality assessment in CBCT images. The effect of scan mode and the use of metal artefact reduction (MAR) algorithm on artefacts suppression were taken in consideration.

methodsTitanium and zirconia dental implants were installed in porcine bone samples and scanned with two CBCT devices with adjustments on scan mode and with the use of MAR. The control group consisted of bone sample without implant and scanned with full-rotation scan mode without MAR. Artefacts extension and bone quality around implants were measured by deviation of grey values and bone histomorphometry measurements (trabecular volume fraction, bone specific surface, trabecular thickness, and trabecular separation), respectively. Mean difference among groups was assessed by within ANOVA with Bonferroni correction. Correlation between bone quality measurements acquired in the experimental and control groups was assessed by Spearman correlation test (α = .05).

resultsNo statistical difference was found for artefacts extension in images acquired by half and full-rotation modes (P = .82). The application of MAR reduced artefacts caused by titanium and zirconia dental implants, showing no statistically significant difference from the control group (titanium: P = .20; zirconia: P = .31). However, there was no correlation between bone quality measurements (P < .05).

conclusionsBone quality assessment was affected by the presence of artefacts caused by dental implants. Rotation mode did not affect the appearance of artefacts and bone qualitative measurements. MAR was able to decrease artefacts, however, it did not improve the accuracy of bone quality measurements.

Indexed as

ArtifactsCone-Beam Computed TomographyDental ImplantsAlgorithmsAnimalsBone DensityRotationSwineTitaniumZirconiumDental ImplantsTitaniumZirconiumzirconium oxideartefactscone-beam CTdental implants

Identifiers

PMID39945860
PMCPMC12038231