Evidence map›Paper›PMID 39945452›Full record

ArticleMedical physics2025

Physics-informed model-based generative neural network for synthesizing scanner- and algorithm-specific low-dose CT exams.

Hao Gong, Lifeng Yu, Shuai Leng, Scott S Hsieh, Joel G Fletcher, Cynthia H McCollough

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hao GongDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Lifeng YuDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Shuai LengDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Scott S HsiehDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Joel G FletcherDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Cynthia H McColloughDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.

Funding

Trade-offs in human observer performance, image quality metrics, and patient doseR01EB017095 · NIBIB · MAYO CLINIC ROCHESTER · PI Hao Gong, Cynthia H McCollough · 2012 to 2026
$7.0M
NIBIB NIH HHS R01 EB017095NIH HHS R01 EB017095
6 · The paper itself

Abstract

backgroundAccurate low-dose CT simulation is required to efficiently assess reconstruction and dose reduction techniques. Projection domain noise insertion requires proprietary information from manufacturers. Analytic image domain noise insertion methods are successful for linear reconstruction algorithms, however extending them to non-linear algorithms remains challenging. Emerging, deep-learning-based image domain noise insertion methods have potential, but few approaches have explicitly incorporated physics information and a texture-synthesis model to guide the generation of locally and globally correlated noise texture. PURPOSE: We proposed a physics-informed model-based generative neural network for simulating scanner- and algorithm-specific low-dose CT exams (PALETTE). It is expected to provide an alternative to projection domain noise insertion methods in the absence of manufacturers' proprietary information and tools.

methodsPALETTE integrated a physics-based noise prior generation process, a Noise2Noisier sub-network, and a noise texture synthesis sub-network. The Noise2Noisier sub-network provided a bias prior, which, combined with the noise prior, served as the inputs to noise texture synthesis sub-network. Explicit regularizations in spatial and frequency domains were developed to account for noise spatial correlation and frequency characteristics. For proof-of-concept, PALETTE was trained and validated for a commercial iterative reconstruction algorithm (SAFIRE, Siemens Healthineers), using the paired routine and 25% dose images from CT phantoms (lateral size 30-40 cm; three training and four testing phantoms) and open-access patient cases (10 training and 20 testing cases). In phantom validation, noise power spectra (NPS) were compared in water background and tissue-mimicking inserts, using peak frequency and mean-absolute-error (MAE). In patient case evaluation, visual inspection and quantitative assessment were conducted on axial, coronal, and sagittal planes. Local and global noise texture were visually inspected in low-dose CT images and the difference images between routine and low dose. Noise levels in liver and fat were measured. Local and global 2D Fourier magnitude spectra of the difference images and the corresponding radial mean profiles were used to assess similarity in noise frequency components within tissues and entire field-of-view, using spectral correlation mapper (SCM) and spectral angle mapper (SAM). Several baseline neural network models (e.g., GAN) were included in the evaluation. Statistical significance was tested using a t-test for related samples.

resultsPALETTE-derived NPS showed accurate noise peak frequency (PALETTE/reference: water 1.40/1.40 lp/cm; inserts 1.7/1.7lp/cm) and small MAE (≤0.65 HU

conclusionPALETTE can provide high-quality image domain noise insertion for simulating accurate low-dose CT images created with a commercial non-linear reconstruction algorithm.

Indexed as

AlgorithmsImage Processing, Computer-AssistedNeural Networks, ComputerRadiation DosageTomography Scanners, X-Ray ComputedTomography, X-Ray ComputedHumansPhantoms, Imagingcomputed tomographyimage domain noise insertionimage quality assessmentphysics informed deep learning

Identifiers

PMID39945452
PMCPMC12151769

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.