Compact and Real-Time Radiation Dosimeter Using Silicon Photomultipliers for In Vivo Dosimetry in Radiation Therapy.

Jeongho Kim, Jeehoon Park, Byungdo Park, Yonghoon Kim, Beomjun Park, So Hyun Park

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jeongho KimDepartment of Radiation Oncology, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon 51353, Republic of Korea.ORCID 0000-0002-7075-8293
Jeehoon ParkDepartment of Radiation Oncology, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon 51353, Republic of Korea.
Byungdo ParkDepartment of Radiation Oncology, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon 51353, Republic of Korea.
Yonghoon KimMarine Radioactivity Monitoring Group, Korea Marine Environment Management Co., Busan 48931, Republic of Korea.
Beomjun ParkInterdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Republic of Korea.ORCID 0000-0002-7822-9919
So Hyun ParkDepartment of Radiation Oncology, Jeju National University Hospital, Jeju 63241, Republic of Korea.

Funding

Korea Institute of Energy Technology and Planning(KETEP) grant funded by the Korean gov-ernment (MOTIE 20214000000070National Research Foundation of Korea (NRF) and funded by the Korean Government (MIST) . 2022R1F1A1059554 and 2022R1F1A1063925
6 · The paper itself

Abstract

Existing dosimeters for radiation therapy are typically large, and their performance in in vivo system applications has not been assessed. This study develops a compact real-time dosimeter using silicon photomultipliers, plastic scintillators, and optical fibers and evaluates its in vivo applicability for radiation therapy. Dose calibration, dose-rate dependency and linearity, and short-term repeatability tests were conducted using solid water phantoms and bolus materials, and in vivo dosimetry was performed using an in-house phantom. The characterization evaluation results showed high linearity, with a coefficient of determination of 0.9995 for dose rates of 100-600 monitoring units (MU)/min, confirming an error rate within 2% when converted to dosage. In the short-term repeatability tests, the dosimeter exhibited good characteristics, with relative standard deviation (RSD) values lower than 2% for each beam delivery and an RSD value of 0.03% over ten beam deliveries. Dose measurements using the phantom indicated an average error rate of 3.83% compared to the values calculated using the treatment planning system. These results demonstrate a performance comparable to that of commercial metal-oxide-semiconductor field-effect transistors and plastic scintillator-based dosimeters. Based on these findings, the developed dosimeter has significant potential for in vivo radiation therapy applications.

Indexed as

In Vivo DosimetryRadiation DosimetersRadiometrySiliconCalibrationHumansPhantoms, ImagingScintillation CountingSilicondosimeteroptical fiberplastic scintillatorradiation therapysilicon photomultiplier