Evidence map›Paper›PMID 39943449›Full record

ArticleSensors (Basel, Switzerland)2025

DyGAT-FTNet: A Dynamic Graph Attention Network for Multi-Sensor Fault Diagnosis and Time-Frequency Data Fusion.

Hongjun Duan, Guorong Chen, Yuan Yu, Chonglin Du, Zhang Bao, Denglong Ma

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hongjun DuanSchool of Intelligent Technology and Engineering, Chongqing University of Science and Technology, No. 20 Daxuecheng East Road, Shapingba District, Chongqing 401331, China.
Guorong ChenSchool of Intelligent Technology and Engineering, Chongqing University of Science and Technology, No. 20 Daxuecheng East Road, Shapingba District, Chongqing 401331, China.ORCID 0009-0008-7186-7417
Yuan YuSchool of Intelligent Technology and Engineering, Chongqing University of Science and Technology, No. 20 Daxuecheng East Road, Shapingba District, Chongqing 401331, China.ORCID 0009-0007-2664-9413
Chonglin DuSchool of Intelligent Technology and Engineering, Chongqing University of Science and Technology, No. 20 Daxuecheng East Road, Shapingba District, Chongqing 401331, China.ORCID 0009-0001-0438-5054
Zhang BaoSchool of Intelligent Technology and Engineering, Chongqing University of Science and Technology, No. 20 Daxuecheng East Road, Shapingba District, Chongqing 401331, China.
Denglong MaXJTU School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.ORCID 0000-0001-9342-626X

Funding

Chongqing Technology Innovation and Application Development Project No.2023TIAD-GPX0007Chongqing University of Science and Technology Graduate Innovation Project 2024 YKJCX2421526
6 · The paper itself

Abstract

Fault diagnosis in modern industrial and information systems is critical for ensuring equipment reliability and operational safety, but traditional methods have difficulty in effectively capturing spatiotemporal dependencies and fault-sensitive features in multi-sensor data, especially rarely considering dynamic features between multi-sensor data. To address these challenges, this study proposes DyGAT-FTNet, a novel graph neural network model tailored to multi-sensor fault detection. The model dynamically constructs association graphs through a learnable dynamic graph construction mechanism, enabling automatic adjacency matrix generation based on time-frequency features derived from the short-time Fourier transform (STFT). Additionally, the dynamic graph attention network (DyGAT) enhances the extraction of spatiotemporal dependencies by dynamically assigning node weights. The time-frequency graph pooling layer further aggregates time-frequency information and optimizes feature representation.Experimental evaluations on two benchmark multi-sensor fault detection datasets, the XJTUSuprgear dataset and SEU dataset, show that DyGAT-FTNet significantly outperformed existing methods in classification accuracy, with accuracies of 1.0000 and 0.9995, respectively, highlighting its potential for practical applications.

Indexed as

dynamic graph structurefault diagnosisgraph neural networkmulti-sensor system

Identifiers

PMID39943449
PMCPMC11820772

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.