Evidence map›Paper›PMID 39943295›Full record

Observational studySensors (Basel, Switzerland)2025

Improving Diagnostic Yield for Analyzing Periodic Electrograms in the Remote Detection of Pacemaker Lead Issues.

Clement Quinonero, Marc Strik, Pierre Antoine Catalan, Pierre Mondoly, Julien Laborderie, Michel Haïssaguerre, Romain Eschalier, Pierre Bordachar, Sylvain Ploux

Abstract readObservational StudyMulticenter Study
In one paragraph

Observational study in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Clement QuinoneroCRCTB (Centre de Recherche Cardio-Thoracique de Bordeaux), INSERM (Institut National de la Santé et de la Recherche Médicale), University Bordeaux, U 1045, IHU Liryc, 33000 Bordeaux, France.
Marc StrikCRCTB (Centre de Recherche Cardio-Thoracique de Bordeaux), INSERM (Institut National de la Santé et de la Recherche Médicale), University Bordeaux, U 1045, IHU Liryc, 33000 Bordeaux, France.ORCID 0000-0003-3348-6548
Pierre Antoine CatalanCardiology Department, CHU Clermont-Ferrand, 63000 Clermont-Ferrand, France.ORCID 0009-0005-0489-144X
Pierre MondolyDepartment of Cardiology, CHU de Toulouse, 31000 Toulouse, France.
Julien LaborderieCardiology Department, CH de la Côte Basque, 64100 Bayonne, France.
Michel HaïssaguerreCRCTB (Centre de Recherche Cardio-Thoracique de Bordeaux), INSERM (Institut National de la Santé et de la Recherche Médicale), University Bordeaux, U 1045, IHU Liryc, 33000 Bordeaux, France.ORCID 0000-0001-7644-6146
Romain EschalierDepartment of Cardiology, CHU de Toulouse, 31000 Toulouse, France.ORCID 0000-0003-3183-7084
Pierre BordacharCRCTB (Centre de Recherche Cardio-Thoracique de Bordeaux), INSERM (Institut National de la Santé et de la Recherche Médicale), University Bordeaux, U 1045, IHU Liryc, 33000 Bordeaux, France.
Sylvain PlouxCRCTB (Centre de Recherche Cardio-Thoracique de Bordeaux), INSERM (Institut National de la Santé et de la Recherche Médicale), University Bordeaux, U 1045, IHU Liryc, 33000 Bordeaux, France.

Funding

Agence Nationale de la Recherche ANR-10-IAHU-04
6 · The paper itself

Abstract

Remote monitoring of pacemakers decreases patient complications and reduces public health expenses. The transmission of passive real-time electrograms (EGM) has been shown to increase the diagnostic yield, but this may add to the work burden. Passive EGMs provide snapshots without adjustments, while active EGMs modify pacemaker settings temporarily to encourage sensing and pacing, potentially revealing issues such as undersensing, oversensing, or loss of capture. The added value of active EGMs compared to the passive EGM remains to be shown. The objective of this multicenter observational study is to evaluate, in a large population of patients implanted with a pacemaker capable of transmitting both passive and active periodic EGMs, the added benefit of active periodic EGMs on diagnostic yield of pacemaker-related anomalies. In a retrospective analysis of 7068 EGMs from 2733 patients, active modes detected significantly more anomalies (6.7%) than passive alone (3.3%,

Indexed as

ElectrocardiographyPacemaker, ArtificialAgedFemaleHumansMaleRetrospective Studiesalgorithmelectrocardiogramlead dysfunctionpacemakerremote

Identifiers

PMID39943295
PMCPMC11820554

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.