Evidence map›Paper›PMID 39942366›Full record

ArticleMaterials (Basel, Switzerland)2025

Dental Implant with Porous Structure and Anchorage: Design and Bench Testing in a Calf Rib Model Study.

Keila Lovera, Vicente Vanaclocha, Carlos M Atienza, Amparo Vanaclocha, Pablo Jordá-Gómez, Nieves Saiz-Sapena, Leyre Vanaclocha

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Keila LoveraCDL Clínica Dental Lovera, Avenida Cornellà, 2-BJ, Esplugues de Llobregat, 08950 Barcelona, Spain.
Vicente VanaclochaFaculty of Medicine and Odontology, Department of Surgery, University of Valencia, 46010 Valencia, Spain.ORCID 0000-0002-4909-5886
Carlos M AtienzaBiomechanics Institute of Valencia, Polytechnic University of Valencia, 46022 Valencia, Spain.
Amparo VanaclochaBiomechanics Institute of Valencia, Polytechnic University of Valencia, 46022 Valencia, Spain.
Pablo Jordá-GómezHospital General Universitario de Castellón, 12004 Castellón de la Plana, Spain.ORCID 0000-0003-0160-4431
Nieves Saiz-SapenaHospital General Universitario de Valencia, 46014 Valencia, Spain.ORCID 0000-0001-7816-3617
Leyre VanaclochaMedius Klinik, Ostfildern-Ruit Klinik für Urologie, Hedelfinger Strasse 166, 73760 Ostfildern, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Primary dental implant stability is critical to enable osseointegration. We assessed the primary stability of our newly designed dental implant. We used the calf rib bone animal model. Our implant has an outside tapered screw with two inside barrettes that deploy with a second screw situated at the implant's crown. We used ten calf ribs with III/IV bone density and inserted ten implants per rib. We deployed the barrettes in the calf rib's transversal direction to support against the nearby cortical bone. We measured the primary implant's stability with resonance frequency analysis and collected the Implant Stability Quota (ISQ) in the transverse and longitudinal calf rib planes before (PRE) and after (POS) deploying the barrette. The mean ISQ was PRE 84.00 ± 3.56 and POS 84.73 ± 4.53 (

Indexed as

3D printingbone–implant interactionsosseointegrationporous implantstitanium implants

Identifiers

PMID39942366
PMCPMC11820065

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked