Evidence map›Paper›PMID 39940123›Full record

ArticleJournal of applied clinical medical physics2025

Patient setup variation on Elekta Unity and its impact on adaptive planning.

Maggie Yan, Erika Kollitz, Sheng-Hsuan Sun, Kathryn Hitchcock, Alexandra De Leo, Amanda Schwarz, Luke Maloney, Jonathan Li, Chihray Liu, Guanghua Yan

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Patient setup variation on Elekta Unity and its impact on adaptive planning.Journal of applied clinical medical physics · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Maggie YanDepartment of Computer Information and Science Engineering, University of Florida, Gainesville, Florida, USA.
Erika KollitzDepartment of Radiation Oncology, University of Florida, Gainesville, Florida, USA.
Sheng-Hsuan SunDepartment of Radiation Oncology, University of Florida, Gainesville, Florida, USA.
Kathryn HitchcockDepartment of Radiation Oncology, University of Florida, Gainesville, Florida, USA.
Alexandra De LeoDepartment of Radiation Oncology, University of Florida, Gainesville, Florida, USA.
Amanda SchwarzDepartment of Radiation Oncology, University of Florida, Gainesville, Florida, USA.
Luke MaloneyDepartment of Radiation Oncology, University of Florida, Gainesville, Florida, USA.
Jonathan LiDepartment of Radiation Oncology, University of Florida, Gainesville, Florida, USA.
Chihray LiuDepartment of Radiation Oncology, University of Florida, Gainesville, Florida, USA.
Guanghua YanDepartment of Radiation Oncology, University of Florida, Gainesville, Florida, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe unique design of the MR-linac may restrict the use of effective immobilization devices, resulting in significant patient setup variations (PSVs). The purpose of this study is to analyze the PSVs on the Elekta Unity system and investigate their impact on adaptive planning.

methodsThe PSVs for 10 brain, 10 pancreas, five prostate, and five rectum patients previously treated on Elekta Unity were analyzed. The five prostate and five pancreas plans were selected to investigate the impact of PSVs on adaptive planning. The reference scans were shifted by 1, 2, and 3 cm in the left-right (LR) and superior-inferior (SI) directions to simulate PSVs. Both the adaptive-to-position (ATP) and adaptive-to-shape (ATS) workflows were executed. The adaptive planning time, number of monitor units (MUs), and dosimetric metrics quantifying target coverage and organ-at-risks (OARs) sparing were compared.

resultsFor brain treatments, the average/maximum PSVs were -0.2 ± 0.3 cm/0.8 cm (LR), 0.3 ± 0.7 cm/1.8 cm (SI), and 0.8 ± 0.7 cm/1.8 cm in the anterior-posterior (AP) direction. For pancreas treatments, the PSVs are -0.1 ± 1.0 cm/3.8 cm (LR), -0.1 ± 0.8 cm/3.5 cm (SI), and 0.3 ± 0.3 cm/1.3 cm (AP). Pelvis treatments had similar PSVs as pancreas treatments. The ATS workflow took two to three times longer than the ATP workflow. The only trend observed was that the plan MUs increased slightly (< 10%) with PSVs in the ATP workflow for prostate patients. Both workflows effectively reproduced target coverage and OAR sparing, regardless of the magnitude of the PSVs.

conclusionsSignificant PSVs were observed on Elekta Unity due to suboptimal patient immobilization. Using prostate and pancreas treatments as examples, we demonstrated that adaptive planning can effectively accommodate such PSVs. Nevertheless, efforts should be made to minimize PSVs-particularly rotations-to mitigate intra-fraction motion and reduce treatment time.

Indexed as

Brain NeoplasmsOrgans at RiskPancreatic NeoplasmsParticle AcceleratorsPatient PositioningProstatic NeoplasmsRadiotherapy Planning, Computer-AssistedRadiotherapy Setup ErrorsRectal NeoplasmsHumansMaleRadiotherapy DosageRadiotherapy, Intensity-Modulatedadaptive planningElekta UnityMR‐linacpatient setup variation

Identifiers

PMID39940123
PMCPMC11969072

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.