ArticleBMC musculoskeletal disorders2025

Measurement of the dynamic axial load-share ratio in vivo could indicate sufficient callus healing in external fixators.

Xuefei Fu, Sida Liu, Na Wang, Yi Ji, Lin Lu, Tao Chen, Mingyong Gu, Zhiwei Chai, Defu Yu, Yancheng Liu and 1 more

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Observational
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Xuefei Fu *Clinical School of Orthopedics, Tianjin Medical University, Tianjin, China.
Sida Liu *School of Mechanical Engineering, Tianjin University, Tianjin, China.
Na Wang *Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China.
Yi JiDepartment of Radiology, Tianjin Union Medical Center, Tianjin, China.
Lin LuDepartment of Radiotherapy, Anhui No. 2 Provincial People's Hospital, Hefei, Anhui, China.
Tao ChenDepartment of Orthopedics, Anhui No. 2 Provincial People's Hospital, Hefei, Anhui, China.
Mingyong GuDepartment of Sports Medicine, Jinan Third People's Hospital, Jinan, Shandong, China.
Zhiwei ChaiUrban Rail Transit Center, China Academy of Railway Sciences Co., Ltd., Beijing, China.
Defu YuDepartment of Orthopedics, Anhui No. 2 Provincial People's Hospital, Hefei, Anhui, China. anhuiyudefu@sina.com.
Yancheng LiuDepartment of Bone and Soft Tissue Oncology, Tianjin Hospital, Tianjin University, Tianjin, China. liutj2001@163.com.
Jun MiaoDepartment of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China. mj6688@tju.edu.cn.

Funding

Natural Science Foundation of Tianjin City No. 23JCZDJC00830
6 · The paper itself

Abstract

backgroundFracture healing is commonly evaluated through physical examination and radiographic results. However, these methods rely on the surgeons' subjective experience, without including the objective biomechanical properties of the bony callus. This paper presents an innovative method for measuring the callus stiffness in vivo to evaluate fracture healing, further instructing surgeons to remove external fixator safely.

methodsA novel dynamic axial load-share ratio (D-LS) index and its associated measuring system was introduced, including the system's composition (hexapod and insole modules), theoretical model, and method for D-LS measurement. From Jan 2022 to May 2024, 36 patients with tibial shaft fracture treated by Taylor Spatial Frame were evaluated in this prospective study. Once the patient had reached clinical bone healing conditions, the in vivo D-LS measurement was conducted. The patients' demographic data, clinical outcomes, particularly D-LS value and refracture rate were recorded.

resultsAt a mean follow-up of 16.50 ± 5.79 months, a total of 36 patients completed the final follow-up. Fixators were removed with an average of 24.81 ± 4.51 weeks. The result of hexapod module's precision examination were maximum errors of 3.72 N, 3.31 N and 2.68 N in x-, y- and z-axis, respectively. The measuring process took an average system installation time of 15.42 ± 4.88 min. Two patients (5.56%) reported fracture site pain. Each patient's D-LS was determined after three rounds of measurement. The average D-LS value was 15.58 ± 2.77% (range, 9.60-20.52%). None of the 36 patients reported refracture at the last follow-up.

conclusionsThe novel D-LS measurement system can measure the dynamic forces of lower limb for patients with external fixator in vivo. An objective biomechanical indicator of the regenerate callus was provided by the D-LS. The D-LS measurement is a complement to standard radiological assessment only after radiologically confirmed bone union. Measuring the D-LS in vivo could indicate whether the callus healing is sufficient in external fixation, and 15.6% (average) was recommended as a reference D-LS value for safe fixator removal.

Indexed as

Bony CallusExternal FixatorsFracture FixationFracture HealingTibial FracturesAdultAgedBiomechanical PhenomenaFemaleFollow-Up StudiesHumansMaleMiddle AgedProspective StudiesWeight-BearingYoung AdultCallus stiffnessDynamic measurementFracture healingGround reaction forceHexapod external fixatorLoad-share ratioPressure insole

Identifiers

PMID39940030
PMCPMC11817624

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.