Evidence map›Paper›PMID 39939647›Full record

ArticleScientific reports2025

Adaptive grid resilient based protection method for multi fault scenarios in medium voltage quintuple DC microgrid system.

S Faazila Fathima, L Premalatha

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

S Faazila FathimaSchool of Electrical Engineering, Vellore Institute of Technology, Chennai, Tamil Nadu, 600127, India.
L PremalathaSchool of Electrical Engineering, Vellore Institute of Technology, Chennai, Tamil Nadu, 600127, India. premalatha.l@vit.ac.in.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Multi-microgrid systems offer a versatile solution to many of the challenges including issues on power glitches, grid flow optimization, stability and protection system malfunction faced by traditional centralized power grids. By enhancing resilience, integrating renewable energy, improving efficiency, and supporting economic and environmental goals, they represent a forward-looking approach to modern energy management. Despite of technological progress in fault current detection, significant challenges oriented to false tripping and protection blinding in multi- microgrid structures compared to single microgrid topology still remain unresolved. The primary aspects that require focus while multigrid resilience includes fast fault detection and interruption, nuisance tripping and blinding of protection. This paper enhances the fault isolation speed by proposing adaptive grid resilient scheme (AGRS) with fault identification method using level order tree traversal (LOTT) and Bidirectional Dial's algorithm, which functions with the assistance of MGMFDS (Microgrid Monitoring Fault Detection System). The presented work analyses the implementation of the proposed adaptive algorithm and tested for various types of faults in a 35-bus quintuple system, where its efficacy in interrupting the fault takes 2.64 ms. The experiments for the proposed work are conducted using a real time simulator for model in loop (MIL) and control hardware in loop (CHIL) testing.

Indexed as

Bidirectional Dial’sFault detectionFault tripping timeLevel order tree traversal (LOTT)Quintuple DC microgridSmart Power Relay (SPR)

Identifiers

PMID39939647
PMCPMC11822095

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390