Evidence map›Paper›PMID 39938896›Full record

ArticleMagnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine2025

Using Deep Learning to Simultaneously Reduce Noise and Motion Artifacts in Brain MR Imaging.

Isao Muro, Tetsuro Isoiwa, Shuhei Shibukawa, Keisuke Usui, Yuhei Otsuka

Abstract read
In one paragraph

Article in Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Isao MuroDepartment of Radiology, Advanced Imaging Center YAESU Clinic, Tokyo, Japan.
Tetsuro IsoiwaDepartment of Radiology, Advanced Imaging Center YAESU Clinic, Tokyo, Japan.
Shuhei ShibukawaDepartment of Radiological Technology, Faculty of Health Science, Juntendo University, Tokyo, Japan.
Keisuke UsuiDepartment of Radiological Technology, Faculty of Health Science, Juntendo University, Tokyo, Japan.
Yuhei OtsukaDepartment of Radiological Technology, Tokai University Hachioji Hospital, Hachioji, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo reduce motion artifacts (MA) and noise in brain MRI using deep learning to promote clinical utility.

methodsT1-weighted (T1W), T2-weighted (T2W), and fluid attenuated inversion recovery (FLAIR) images of the brain (including sagittal, coronal, and axial sections) of 20 healthy volunteers were collected using a 3.0T MR system. Simulated images with horizontal and vertical phase directions exhibiting varying white noise and MA (n = 115200) were created for each sequence and trained in deep learning (36000 pairs), validation (200 pairs), and testing (200 pairs, 2000 pairs) datasets. Images with MA and noise and images without MA and noise were included. A training model was constructed to remove noise and MA. The model's ability to remove noise and MA was evaluated by the structural similarity index (SSIM) and peek signal to noise ratio (PSNR). The SSIM and PSNR between the ground-truth and output images were calculated (SSIMout, PSNRout), and the SSIM and PSNR between the ground-truth and input images were calculated (SSIMinp, PSNRinp). The ratio of SSIMinp to SSIMout was then evaluated as the improvement ratio of SSIM (IMPRs) and the ratio of PSNRinp to PSNRout as the improvement ratio of PSNR (IMPRp). In addition, 10 radio technologists performed visual evaluation.

resultsThe SSIMout were >0.95 and 33 dB, respectively, for T1W, T2W, and FLAIR images with different contrasts. The mean value of SSIMinp was 0.72. Noise and MA removal effects were observed in images, with an average value of 72 dB. Visual evaluation revealed that the reduction effect in the output image was higher than that observed in the input image.

conclusionThe method proposed herein, which uses separate training models for the T1W, T2W, and FLAIR sequences, is a valuable approach for removing MA and noise, independent of the imaging direction and artifact orientation. An improvement in image quality was achieved by generating a large amount of training data through simulation.

Indexed as

ArtifactsBrainDeep LearningImage Processing, Computer-AssistedMagnetic Resonance ImagingAdultAlgorithmsFemaleHealthy VolunteersHumansMaleMotionSignal-To-Noise RatioYoung Adultbraindeep learningnoise and motion artifacts reductionsimulationU-Net

Identifiers

PMID39938896
PMCPMC12671233

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.