Evidence map›Paper›PMID 39936243›Full record

ArticleACS nano2025

Piezoresistive Platinum Diselenide Pressure Sensors with Reliable High Sensitivity and Their Integration into Complementary Metal-Oxide-Semiconductor Circuits.

Sebastian Lukas, Nico Rademacher, Sofía Cruces, Michael Gross, Eva Desgué, Stefan Heiserer, Nikolas Dominik, Maximilian Prechtl, Oliver Hartwig, Cormac Ó Coileáin and 7 more

Abstract read
In one paragraph

Article in ACS nano, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Impact of Strain in Free-Standing PtSeAdvanced materials (Deerfield Beach, Fla.) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

17 authors.

Sebastian LukasChair of Electronic Devices, RWTH Aachen University, Otto-Blumenthal-Str. 25, 52074 Aachen, Germany.ORCID 0000-0002-8062-2832
Nico RademacherChair of Electronic Devices, RWTH Aachen University, Otto-Blumenthal-Str. 25, 52074 Aachen, Germany.
Sofía CrucesChair of Electronic Devices, RWTH Aachen University, Otto-Blumenthal-Str. 25, 52074 Aachen, Germany.
Michael GrossChair of Electronic Devices, RWTH Aachen University, Otto-Blumenthal-Str. 25, 52074 Aachen, Germany.ORCID 0009-0001-9072-8200
Eva DesguéTHALES R&T, 1 Av. Augustin Fresnel, 91767 Palaiseau, France.
Stefan HeisererInstitute of Physics & SENS Research Centre, University of the Bundeswehr Munich, Werner-Heisenberg-Weg 39, 85577 Neubiberg, Germany.
Nikolas DominikInstitute of Physics & SENS Research Centre, University of the Bundeswehr Munich, Werner-Heisenberg-Weg 39, 85577 Neubiberg, Germany.
Maximilian PrechtlInstitute of Physics & SENS Research Centre, University of the Bundeswehr Munich, Werner-Heisenberg-Weg 39, 85577 Neubiberg, Germany.
Oliver HartwigInstitute of Physics & SENS Research Centre, University of the Bundeswehr Munich, Werner-Heisenberg-Weg 39, 85577 Neubiberg, Germany.ORCID 0000-0002-5409-4124
Cormac Ó CoileáinInstitute of Physics & SENS Research Centre, University of the Bundeswehr Munich, Werner-Heisenberg-Weg 39, 85577 Neubiberg, Germany.
Tanja Stimpel-LindnerInstitute of Physics & SENS Research Centre, University of the Bundeswehr Munich, Werner-Heisenberg-Weg 39, 85577 Neubiberg, Germany.
Pierre LegagneuxTHALES R&T, 1 Av. Augustin Fresnel, 91767 Palaiseau, France.
Arto RantalaVTT Technical Research Centre of Finland Ltd, P.O. Box 1000, FI-02044 VTT, Espoo, Finland.
Juha-Matti SaariVTT Technical Research Centre of Finland Ltd, P.O. Box 1000, FI-02044 VTT, Espoo, Finland.
Miika SoikkeliVTT Technical Research Centre of Finland Ltd, P.O. Box 1000, FI-02044 VTT, Espoo, Finland.ORCID 0000-0002-8014-7875
Georg S DuesbergInstitute of Physics & SENS Research Centre, University of the Bundeswehr Munich, Werner-Heisenberg-Weg 39, 85577 Neubiberg, Germany.ORCID 0000-0002-7412-700X
Max C LemmeChair of Electronic Devices, RWTH Aachen University, Otto-Blumenthal-Str. 25, 52074 Aachen, Germany.ORCID 0000-0003-4552-2411

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Membrane-based sensors are an important market for microelectromechanical systems (MEMS). Two-dimensional (2D) materials, with their low mass, are excellent candidates for suspended membranes to provide high sensitivity, small footprint sensors. The present work demonstrates pressure sensors employing large-scale-synthesized 2D platinum diselenide (PtSe

Indexed as

2D materialsCMOSMEMSplatinum diselenidepressure sensor

Identifiers

PMID39936243
PMCPMC11867020

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.