Evidence map›Paper›PMID 39931607›Full record

ArticleCureus2025

Visual Measurements of Breathing Parameters in Children With a Particular Focus on Phase Angle: A Pilot Study.

Israel Amirav, Alon Zvirin, Sapir V Levi, Neta Rabin, Yaron Honen, Or Marudi, Daphna Vilozni, Moran Lavie, Ron Kimmel

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Israel AmiravDepartment of Pediatrics, Ichilov Hospital, Tel Aviv, ISR.
Alon ZvirinDepartment of Computer Science, Technion - Israel Institute of Technology, Haifa, ISR.
Sapir V LeviDepartment of Pediatrics, Montefiore Medical Center, Wakefield Campus, Bronx, USA.
Neta RabinDepartment of Pediatric Pulmonology, Tel Aviv Sourasky Medical Center, Tel Aviv, ISR.
Yaron HonenDepartment of Computer Science, Technion - Israel Institute of Technology, Haifa, ISR.
Or MarudiDepartment of Pediatric Pulmonology, Tel Aviv Sourasky Medical Center, Tel Aviv, ISR.
Daphna VilozniDepartment of Pediatric Pulmonology, Tel Aviv Sourasky Medical Center, Tel Aviv, ISR.
Moran LavieDepartment of Pediatric Pulmonology, Tel Aviv Sourasky Medical Center, Tel Aviv, ISR.
Ron KimmelDepartment of Electrical and Computer Engineering, Technion - Israel Institute of Technology, Haifa, ISR.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Pediatric respiratory monitoring, crucial for assessing children's health, particularly those with respiratory diseases, often relies on invasive or cumbersome methods. Here, we propose a non-invasive approach using a video depth camera to measure breathing parameters in children, offering innovation and promise. Aims We aim to introduce and validate a straightforward remote procedure for measuring crucial breathing parameters in children. These include respiratory rate (RR), volumetric changes during inhalation and exhalation, and the phase angle (PA) between chest and abdomen expansions. Methods The proposed method involves detecting three feature points - nipples and navel - using a video depth camera. A 30- to 60-second video is recorded to track chest and abdomen movements. Analysis of feature point locations, distances between them, and signal frequencies is conducted to estimate respiratory parameters. To validate the accuracy of our method, we employed mechanical lung simulators within dolls for procedure testing and measurement accuracy verification. Additionally, recordings of pediatric patients, both healthy and with respiratory diseases, were analyzed to correlate computational parameter estimations with physician assessments, ensuring the reliability and effectiveness of our approach. Results Our results show a strong correlation between simulator inputs and algorithm estimations, validating our method's accuracy. Additionally, applying the procedure to pediatric patient recordings significantly correlates with physician assessments, notably, marking the first remote measurement of the respiratory PA. Conclusions This remote procedure presents a promising alternative for pediatric respiratory monitoring, offering accurate measurements without invasive techniques or extensive equipment. The robust correlation between computational estimations and physician assessments underscores its reliability, suggesting potential for broader clinical applications and advancements in pediatric respiratory care.

Indexed as

phase anglephase shiftremote monitoringrespiratory ratetidal volume

Identifiers

PMID39931607
PMCPMC11810438

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.