ArticleHeliyon2025
Microbial inactivation and emission of volatile organic compounds in low-heat thermal treatment of infectious healthcare waste.
Article in Heliyon, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The growing use of low-temperature waste decontamination devices in hospitals has raised concerns about their inactivation efficiencies and emissions of volatile organic compounds (VOCs). This study evaluated the decontamination efficiencies, as well as VOC and ammonia emissions, of sterilizer devices in four hospitals, including two autoclaves (one with a shredder and one without), a hydroclave, and a dry heating device. Decontamination efficiency was assessed using mechanical and biological indicators, while air pollutants, including VOCs and ammonia, were measured according to National Institute for Occupational Safety and Health (NIOSH) methods. Evaluation of decontamination revealed that the autoclave with a shredder achieved the highest efficiency (up to 100 %), highlighting the importance of shredding, while the autoclave without a shredder demonstrated the lowest performance. Maintaining an appropriate temperature was also identified as a reliable indicator of device efficiency. The hydroclave exhibited the highest VOC and ammonia emissions (128.03 mg/m³ for VOCs and 6.48 mg/m³ for ammonia), while the autoclaves had the lowest ones (45.72 mg/m³ for VOCs and 2.58 mg/m³ for ammonia). The three major VOCs emitted from the sterilizer devices included dichloromethane, ethyl alcohol, and ethyl acetate (with a total level of 22.82 mg/m³). VOC and ammonia emissions were affected by device operational factors and waste composition. These findings highlighted the critical need to optimize hospital waste management practices. Adhering to operational parameters that directly influence device efficiency, along with equipping low-temperature sterilization devices with air pollutant control systems, can significantly minimize emissions, thereby reducing occupational health risks and environmental impacts.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.