Evidence map›Paper›PMID 39930153›Full record

ArticleScientific reports2025

Lightweight mechanical equipment fault diagnosis framework based on GCGAN-MDSCNN-ICA model.

Longyi Liu, Yanqing Zhao, Yi Hu, Yongze Ma, Zhimin Guo

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Longyi Liu *Shenyang Institute of Computing Technology, Chinese Academy of Sciences, Shenyang, 110168, China.
Yanqing Zhao *Shenyang Institute of Computing Technology, Chinese Academy of Sciences, Shenyang, 110168, China.
Yi HuShenyang Institute of Computing Technology, Chinese Academy of Sciences, Shenyang, 110168, China. Huyi@sict.ac.cn.
Yongze MaShenyang Institute of Computing Technology, Chinese Academy of Sciences, Shenyang, 110168, China.
Zhimin GuoShenyang Institute of Computing Technology, Chinese Academy of Sciences, Shenyang, 110168, China.

Funding

National High-Quality Development Special Project - Quality and Reliability Service Platform for Typical Material Reduction Equipment and Key Functional Components 2022-232-223-01
6 · The paper itself

Abstract

In response to the challenges posed by imbalanced failure diagnosis samples, limited labeled data, and significant computational costs in actual industrial production settings, this paper introduces a high-precision, low-resource, end-to-end fault diagnosis framework. On one hand, we propose a data augmentation method based on GCGAN, which combines CNN and GRU to construct core network structures for the generator and discriminator. We integrate a novel Smoothed Hinge-Cross-Entropy loss function to facilitate the training process, effectively mitigating mode collapse and vanishing gradient issues. On the other hand, we design a lightweight fault diagnosis model based on MDSCNN-ICA-BiGRU. By substituting standard convolutions with depthwise separable convolutions on deeper channels, the model complexity is significantly reduced, facilitating effective extraction of multiscale spatial features. The improved Coordinate Attention (CA) mechanism filters out noise and enhances the extraction of high-frequency characteristics. Combined with BiGRU, the model captures global temporal associations, achieving a fusion of spatiotemporal features. Experimental results demonstrate that the proposed approach performs well on both publicly available simulation datasets and private laboratory datasets. Compared to other benchmark methods, the GCGAN module significantly enhances data augmentation, improving classification accuracy on CNNs by 10%. When compared with classic convolutional networks such as DRSN and WDCNN, our MDSCNN-ICA-BiGRU shows faster and more stable convergence rates, with near-100% accuracy on test sets and an average computation cost reduction of approximately 70%. Even in noisy environments, our method maintains high accuracy with a slow rate of precision decay, indicating robustness and generalization capabilities.

Identifiers

PMID39930153
PMCPMC11811228

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.