Evidence map›Paper›PMID 39928630›Full record

ArticlePloS one2025

Validity of heart rate measurements in wrist-based monitors across skin tones during exercise.

Stanley Hughwa Hung, Kelsey Serwa, Gillian Rosenthal, Janice J Eng

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Review
  12. Review
  13. Review
  14. Article
  15. Article
  16. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Stanley Hughwa HungDepartment of Physical Therapy, The University of British Columbia, Vancouver, British Columbia, Canada.ORCID https://orcid.org/0000-0001-8725-8036
Kelsey SerwaDepartment of Physical Therapy, The University of British Columbia, Vancouver, British Columbia, Canada.
Gillian RosenthalDepartment of Physical Therapy, The University of British Columbia, Vancouver, British Columbia, Canada.
Janice J EngDepartment of Physical Therapy, The University of British Columbia, Vancouver, British Columbia, Canada.ORCID https://orcid.org/0000-0002-2093-0788

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the accuracy of a wrist-based heart rate (HR) monitor at different exercise intensities across different skin tones.

methodsUsing a cross-sectional design, we compared HR measures from the wrist-based photoplethysmography Fitbit Charge 5 to the Polar H10 chest strap at rest and during the YMCA Protocol using a recumbent cycle ergometer. Participant were grouped into three skin tone categories: light (Fitzpatrick Scale Skin Types 1+2), medium (Types 3+4), and darker skin tone (Types 5+6). HR measures using the Polar chest strap during the exercise test were categorized as <40%, 40-60%, or >60% HR reserve (HRR). Absolute error in beats per minute (bpm) between the two devices was calculated for each measure. A linear mixed effects model was used to assess interaction effects between skin tone and exercise intensity, with participants as the random effect. Bland-Altman plots were used for visual analyses.

resultsTwenty-five participants [mean (SD): 25.8 (1.9) years old; 64% female] were included with 495 observations of simultaneous Fitbit and Polar HR recordings collected during exercise. During exercise, we observed a statistically significant interaction effect between skin tone and exercise intensity. Compared with light skin tone at <40% HRR, mean error was greater for medium skin tone at >60% HRR [mean error (95%CI): 11.8 (5.6-17.9) bpm, p<0.001] and darker skin tone at 40-60% HRR [7.6 (1.7-13.5) bpm, p = 0.011] and >60% HRR [11.7 (5.3-18.0) bpm, p<0.001].

conclusionHR measurement error using a wrist-based device was greater with increasing exercise intensity for people with darker skin tones.

Indexed as

ExerciseHeart RateSkin PigmentationWristAdultCross-Sectional StudiesExercise TestFemaleHumansMalePhotoplethysmographyYoung Adult

Identifiers

PMID39928630
PMCPMC11809914

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.