ArticleJournal of medical physics
A Simulation Study for Optimal Pinhole Collimator Design in Gamma Camera Systems.
Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Impact of Collimator Material on Spatial Resolution and Sensitivity in Semiconductor-Based Imaging Systems: A Monte Carlo Evaluation.Indian journal of nuclear medicine : IJNM : the official journal of the Society of Nuclear Medicine, IndiaArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: The usage of a semiconductor detector with a pinhole collimator can provide high spatial resolution due to its high intrinsic resolution. However, the collimator system has low sensitivity due to the hole's small diameter. Therefore, the optimization between the spatial resolution and sensitivity is critical for determining the image quality in the gamma camera system. Aims and Objectives: A pinhole collimator was designed and simulated to achieve the desired level of resolution and sensitivity in a gamma camera by utilizing a CdTe semiconductor detector. Materials and Methods: To conduct this objective, a simulation toolkit based on the Geant4 Application for Tomographic Emission (GATE) was employed. The imaging capabilities of the proposed system were assessed by varying the magnification factor and pinhole diameter to estimate spatial resolution and sensitivity. Moreover, a hot rod phantom was designed to evaluate the system's overall imaging functionality. Results: Results revealed that an increase in the pinhole diameter was correlated with an increase in sensitivity, while the spatial resolution was decreasing. There were distinct variations in sensitivity and spatial resolution depending on changes in the magnification factor as well. Finally, by analyzing trade-off curves, 1.38±0.081 mm was approximately the optimal pinhole diameter for our proposed system. Conclusion: The optimum position for a pinhole collimator with a CdTe semiconductor detector was demonstrated.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.