ArticleConference proceedings. International Conference on Image Formation in X-Ray Computed Tomography2024
Quantitative metal artifact reduction algorithm for spectral CT thermometry.
Article in Conference proceedings. International Conference on Image Formation in X-Ray Computed Tomography, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Dual-Layer Spectral CT for in Vivo Thermometry During Thermal Ablation.Cardiovascular and interventional radiology · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Spectral CT thermometry can non-invasively monitor internal temperatures to reduce local tumor recurrences caused by insufficient heating/treatment of the tumor and its surrounding safety margin. For its clinical translation, the applied metal artifact reduction algorithm requires quantitative accuracy to ensure the accuracy of generated temperature maps. The newly developed Spectrally Obtained Needle Artifact Reduction (SONAR) algorithm leverages the known shape of the applicator and spectral CT's material decomposition capabilities to isolate the applicator in projections. Projections with long path lengths through metal were then corrected by replacing them with modeled projections of an angled cylinder. To evaluate the accuracy of SONAR, a liver-mimicking phantom embedded with an ablation applicator and thermometers was scanned with a dual-layer spectral CT at phantom temperatures of 35 and 80 °C. Using spectral CT thermometry, temperature maps at 80 °C were generated for image slices with and without the applicator. SONAR significantly decreased streaks along the axis of the applicator. It also eliminated underestimated temperatures immediately adjacent to the applicator and overestimated temperatures in the periphery (2-3 cm from applicator). While application of SONAR resulted in minimal absolute difference in the temperature map without the applicator, averaging 1.1 ± 0.8 °C, temperatures decreased 7.0 ± 4.0 and 10.1 ± 2.3 °C at distances of 2-3 and 0.5-1 cm from the applicator, respectively, to better match the expected temperature. SONAR ultimately minimized metal artifacts and lessened overestimation of temperature in spectral CT thermometry maps. These quantitatively accurate maps will facilitate the
Indexed as
Identifiers
39925380PMC11807397What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.