Evidence map›Paper›PMID 39924766›Full record

ArticleOrthopaedic surgery2025

Robot-Assisted Screw Fixation Combined With Endoscopic Bone Graft in the Minimally Invasive Treatment of Lumbar Spondylolysis: A Single-Center Retrospective Study.

Guanjie Zeng, Zongze Li, Juedong Hou, Liu Yu, Yuhui Cui, Yongjian Zhu, Ling Yao, Jiarui Chen, Yongquan Cheng, Jianting Chen

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Guanjie ZengDivision of Spine Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Zongze LiDivision of Spine Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Juedong HouDivision of Spine Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Liu YuDepartment of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China.
Yuhui CuiDepartment of Medical Imaging Center, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Yongjian ZhuDivision of Spine Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Ling YaoDivision of Spine Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Jiarui ChenShenzhen Futurtec Medical Co. Ltd, Shenzhen, China.
Yongquan ChengDivision of Spine Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Jianting ChenDivision of Spine Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China.ORCID https://orcid.org/0000-0002-6086-0577

Funding

National Natural Science Foundation of China 82172492Science and Technology Planning Project of Guangdong Province 2017B010110012
6 · The paper itself

Abstract

objectiveSpondylolysis, often progressing to spondylolisthesis, commonly defies conservative treatment in refractory cases, indicating a need for surgery. Robot-assisted techniques may provide a stable and effective minimally invasive approach for the treatment of lumbar spondylolysis. To compare the clinical efficacy between robot-assisted percutaneous screw fixation combined with endoscopic bone graft and conventional open screw fixation with bone graft in the treatment of lumbar spondylolysis.

methodsA cohort study involving 43 individuals with lumbar spondylolysis who underwent surgical treatment was conducted. From January 2022 to June 2023, 20 patients underwent percutaneous screw fixation combined with endoscopic bone graft while 23 patients underwent conventional open screw fixation with bone graft. The demographic data, parameters related to robotic surgery, perioperative indicators, VAS and ODI scores, pedicle screw accuracy, radiographic fusion outcomes, and follow-up results were systematically recorded, analyzed, and then compared between the two groups. Categorical variables were analyzed using chi-square tests, and continuous variables were evaluated with t-tests or Mann-Whitney U tests following normality assessment, with statistical significance at p < 0.05.

resultsCompared with the conventional surgery group, the robot-assisted surgery group had significantly less intraoperative blood loss, less postoperative drainage, shorter hospital stay, less intraoperative fluoroscopy times, and radiation exposure dose (p < 0.05). Nevertheless, the duration of the surgery was longer. Postoperative imaging findings showed high screw accuracy in both groups, with a grade A rate of 95% in the robot-assisted group compared with 91.4% in the conventional open surgery group according to the Gertzbein-Robbins scale. Both groups achieved similar improvements in VAS and ODI during 1-year follow-up, and both groups achieved good bone graft fusion (97.5% fusion rate in the robot-assisted group versus 93.5% in the conventional open surgery group).

conclusionRobot-assisted screw fixation combined with endoscopic bone graft provides a safe and reliable minimally invasive treatment of lumbar spondylolysis, with high accuracy of pedicle screw implantation and less radiation exposure dose, less intraoperative trauma, and quicker recovery than conventional open surgery.

Indexed as

Bone TransplantationEndoscopyLumbar VertebraeMinimally Invasive Surgical ProceduresPedicle ScrewsRobotic Surgical ProceduresSpondylolysisAdultAgedFemaleHumansMaleMiddle AgedRetrospective StudiesSpinal Fusionlumbar spondylolysisminimally invasive surgerypedicle screwrobot‐assisted surgeryspinal endoscopy

Identifiers

PMID39924766
PMCPMC11962271

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.