Evidence map›Paper›PMID 39923217›Full record

ArticleUpdates in surgery2025

Surgical techniques using low-power monopolar scissors in robotic-assisted thoracic surgery.

Tatsuo Nakagawa, Yuki Ohsumi, Ei Miyamoto, Masashi Gotoh

Abstract read
PubMed Publisher
In one paragraph

Article in Updates in surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Tatsuo NakagawaDepartment of Thoracic Surgery, Tenri Hospital, 200 Mishima, Tenri, Nara, 632-8552, Japan. tn250765@gmail.com.ORCID http://orcid.org/0000-0002-4944-2884
Yuki OhsumiDepartment of Thoracic Surgery, Tenri Hospital, 200 Mishima, Tenri, Nara, 632-8552, Japan.
Ei MiyamotoDepartment of Thoracic Surgery, Tenri Hospital, 200 Mishima, Tenri, Nara, 632-8552, Japan.
Masashi GotohDepartment of Thoracic Surgery, Tenri Hospital, 200 Mishima, Tenri, Nara, 632-8552, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We analyzed the electrical characteristics of the da Vinci system's low-power monopolar coagulation mode with an electrocautery analyzer to determine its suitability as an alternative to monopolar soft coagulation mode. The voltage at the plateau of the power limit between 15 and 16 W and between 23 and 24 W of the forced coagulation mode of the da Vince system was close to that of the effect 8 and 10 of the soft coagulation mode, respectively. Experiments using chicken meat and an infrared thermographic camera confirmed the safety and effectiveness of low-power monopolar coagulation mode showing no carbonization at temperatures below 90 °C. In 73 robotic-assisted lung resection using low-power coagulation mode, no electric spark or carbonization was observed and all cauterizations were similar to soft coagulation mode. In conclusion, Forced coagulation mode of the da Vinci system can be used as an alternative to monopolar soft coagulation mode with appropriate effect and power limit settings.

Indexed as

ElectrocoagulationPneumonectomyRobotic Surgical ProceduresThoracic Surgical ProceduresAnimalsChickensEquipment DesignHumansMonopolar scissorsRobotic-assisted surgerySoft coagulation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.