Evidence map›Paper›PMID 39920254›Full record

ArticleScientific reports2025

An indoor positioning method based on bluetooth array/PDR fusion using the SVD-EKF.

Chenhui Li, Jie Zhen, Jianxin Wu

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Chenhui LiSchool of Geographical Sciences, Xinyang Normal University, Xinyang, 464000, China. lichenhui@xynu.edu.cn.
Jie ZhenChinese Academy of Surveying and Mapping, Beijing, 100830, China.
Jianxin WuSchool of Electronics and Communication Engineering, Sun Yat-Sen University, Shenzhen, 518107, China.

Funding

National Key Research and Development Program of China 2022YFC3005705
6 · The paper itself

Abstract

With the development of mobile internet and artificial intelligence, the core of current surveying and mapping science and technology is no longer confined solely to outdoor applications. High-precision indoor positioning technology is now one of the core technologies in the era of artificial intelligence. An angle measurement and positioning system based on wireless signal array antennas can achieve high accuracy in indoor unblocked conditions. However, indoor environment is unpredictable, and the user's behavior is also random. Inevitably, some signal reflection and other factors will affect the positioning accuracy. Considering all the aforementioned, this study analyzes the principles and characteristics of a Bluetooth signal based array antenna angle measurement and positioning system. In addition, aiming at the multi-phase problem caused by antenna switching, the frequency estimation method based on FFT (Fast Fourier Transform) is studied in this paper, achieving high-precision angle measurement and positioning. Aiming at the problem that the system positioning error increase in the complex and variable indoor environment, a fusion positioning method of Bluetooth array/PDR (Pedestrian Dead Reckoning) based on the SVD-EKF (Singular Value Decomposition-Extended Kalman Filter) is proposed. This study introduces a few improvements to the EKF (Extended Kalman Filter). First, the predicted state covariance matrix is decomposed by singular value decomposition, which improves the robustness of the EKF. Second, a Bluetooth array self-evaluation factor is introduced and combined with the Huber function to construct an adaptive factor, thus further enhancing filtering accuracy and environmental adaptability. Through static and dynamic data collected in indoor environment, the feasibility of the algorithm is verified. The results of static and dynamic experimental results show that the array angle measurement and positioning system can achieve high accuracy, the near point positioning maximum error is 0.3m and the far point positioning accuracy is 0.6m. The dynamic test results in the room show that after SVD-EKF algorithm optimization, the positioning error is reduced by 0.05m, which is equivalent to the EKF algorithm. However, in corridor areas, the improvement of accuracy of SVD-EKF algorithm is better than EKF, achieving an improvement of 0.373 m and a smoother positioning result compared to the traditional EKF algorithm. This study provides a new practical technology with a high precision and easy deployment for indoor positioning.

Identifiers

PMID39920254
PMCPMC11805997

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked