Evidence map›Paper›PMID 39919182›Full record

ArticleScience advances2025

Instant variable stiffness in cardiovascular catheters based on fiber jamming.

Yi Sun, Yegor Piskarev, Etienne H Hofstetter, Cedric Fischer, Quentin Boehler, Zdeněk Stárek, Bradley J Nelson, Dario Floreano

Abstract read
In one paragraph

Article in Science advances, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Stable magnetic soft structures.Science advances · 2025
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yi SunLaboratory of Intelligent Systems, École Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland.ORCID 0000-0002-0906-5682
Yegor PiskarevLaboratory of Intelligent Systems, École Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland.ORCID 0000-0001-9003-6792
Etienne H HofstetterLaboratory of Intelligent Systems, École Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland.
Cedric FischerMulti-Scale Robotics Laboratory, Eidgenössische Technische Hochschule Zürich, 8092 Zürich, Switzerland.
Quentin BoehlerMulti-Scale Robotics Laboratory, Eidgenössische Technische Hochschule Zürich, 8092 Zürich, Switzerland.ORCID 0000-0001-7573-3135
Zdeněk Stárek1st Department of Internal Medicine, Cardioangiology, St. Anne's University Hospital in Brno and Faculty of Medicine of Masaryk University, Brno, Czech Republic.ORCID 0000-0002-9510-1386
Bradley J NelsonMulti-Scale Robotics Laboratory, Eidgenössische Technische Hochschule Zürich, 8092 Zürich, Switzerland.ORCID 0000-0001-9070-6987
Dario FloreanoLaboratory of Intelligent Systems, École Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland.ORCID 0000-0002-5330-4863

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Variable stiffness (VS) has revolutionized miniature surgical instruments, including cardiovascular catheters for minimally invasive surgeries (MISs), enabling advanced capabilities in stiffness modulation and multi-curvature bending. However, existing VS catheters with phase-changing materials are slow in softening and stiffening rates (≈90 s), which can lead to substantial increase in surgery duration. To address the slow stiffness change, we propose a VS catheter based on fiber jamming (FJ) that achieves instant stiffness changes (≤300 ms), enabling seamless catheter operations without delays. Moreover, our catheter, incorporating hundreds of ultrathin fibers into a slender 2.3-mm catheter body, achieves up to 6.5-fold stiffness changes. With adequate stiffness change, our two-segment catheter achieves complex bending profiles within seconds. In addition, the FJ-based design does not require electric currents or heating inside the human body, minimizing patient risks. This FJ-based VS catheter, with instantaneous response, adequate stiffness change, and enhanced safety, can potentially establish benchmarks in MIS, allowing medical practitioners to effectively address formidable diseases.

Indexed as

Cardiac CathetersMinimally Invasive Surgical ProceduresAnimalsEquipment DesignHeartHumansMaterials TestingModels, Anatomic

Identifiers

PMID39919182
PMCPMC11804929

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked