Evidence map›Paper›PMID 39917242›Full record

ArticleBioinformation2024

Stability analysis of elastomeric impression materials after antimicrobial disinfection.

Santosh T, Pushkar Gupta, Omar Basheer Altaher Mohammed, Aditi M Paranjpe, Harsh Chansoria, Abhishek Pathak, Dayanand Huddar, Sanchari Bhowmick

Abstract read
In one paragraph

Article in Bioinformation, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Santosh TDepartment of Oral Pathology & Microbiology, Vananchal Dental College & Hospital, Garhwa, Jharkhand, India.
Pushkar GuptaDepartment of Prosthodontics and Crown & Bridge, Hitkarini Dental College and Hospital, Jabalpur, M.P, India.
Omar Basheer Altaher MohammedDepartment of Oral and Maxillofacial Surgery, Sebha Dental Faculty, Sebha University, Libya.
Aditi M ParanjpeDepartment of Prosthodontics and Crown & Bridge, Hitkarini Dental College and Hospital, Jabalpur, M.P, India.
Harsh ChansoriaDepartment of Prosthodontics and Crown and Bridge, Government College of Dentistry, Indore, Madhya Pradesh, India.
Abhishek PathakDepartment of Prosthodontics and Crown & Bridge, Hitkarini Dental College and Hospital, Jabalpur, M.P, India.
Dayanand HuddarDepartment of Prosthodontics, Bharati Vidyapeeth Dental College and Hospital, Sangli, Maharashtra, India.
Sanchari BhowmickIntern, Kalinga Institute of Dental Sciences, KIIT Deemed to be University, Bhubaneswar, Odisha, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Impression materials used for replication of dental structures frequently come into touch with blood and saliva during the impression operation. Hence, disinfection of impression mistrials is needed. Therefore, it is of interest to evaluate the effects of three different disinfectants on the antibacterial activity and dimensional stability of the elastomeric impression material. According to American Dental Association (ADA) specification number 19 compliant, a stainless steel master die was constructed. Using vinyl polysiloxanes (VPS) impression medium, thirty samples were produced on this die in accordance with the manufacturer's instructions. To finish the disinfection process, thirty samples were randomly assigned to each of the three groups: Group I consisted of diluted water (control group), Group II consisted of 5.25 percent sodium hypochlorite (NaOCl), and Group III consisted of ozone gas and Group IV - UV radiation. The dimensional stability was evaluated using a stereomicroscope with a 20x magnification and image research software. The antibacterial efficacy of each disinfectant was assessed. In the VPS impression material, the control group exhibited the greatest number of dimensional changes, with ozone gas and 5.25% NaOCl showing the least amount of dimensional changes. The groups were found to differ statistically significantly from one another. The results of the investigation indicate that the VPS elastomeric impression showed very minor dimensional changes when submerged in different disinfectants. In a clinical setting, samples cleaned with 5.25% hypochlorite can be kept for a long time because the consequent dimensional changes are minimal. Ozone gas, UV radiation and sodium hypochlorite showed a reduction in the amount of bacteria.

Indexed as

dimensional changesDisinfectionelastomeric impressionsterilisation

Identifiers

PMID39917242
PMCPMC11795470

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.