Evidence map›Paper›PMID 39915885›Full record

ArticleArthroplasty (London, England)2025

Optimizing implant positioning in total hip arthroplasty via the direct anterior approach: The role and technique of conventional traction table and fluoroscopy.

Seiya Ishii, Tomonori Baba, Koju Hayashi, Yasuhiro Homma, Osamu Muto, Muneaki Ishijima

Abstract read
In one paragraph

Article in Arthroplasty (London, England), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Seiya IshiiDepartment of Orthopaedic Surgery, Yokohama Tsurugamine Hospital, Kanagawa, 241-0011, Japan. seishii@juntendo.ac.jp.ORCID http://orcid.org/0000-0001-6702-4777
Tomonori BabaDepartment of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, 113-0033, Japan.
Koju HayashiDepartment of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, 113-0033, Japan.
Yasuhiro HommaDepartment of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, 113-0033, Japan.
Osamu MutoDepartment of Orthopaedic Surgery, Yokohama Tsurugamine Hospital, Kanagawa, 241-0011, Japan.
Muneaki IshijimaDepartment of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, 113-0033, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPrecise implant positioning during total hip arthroplasty (THA) is an important factor influencing dislocation rate and long-term implant survival. Although a special carbon fiber traction table for THA improves the accuracy of implant positioning, it is too expensive. We aimed to report the accuracy of cup positioning and complication rate in patients undergoing THA via the direct anterior approach using a conventional noncarbon fiber traction table, which is generally used for osteosynthesis of femoral fractures.

methodsThis retrospective study included 101 patients who received primary THA via the direct anterior approach using a conventional traction table with fluoroscopy between July 2022 and October 2024. Two observers evaluated radiological outcomes using postoperative anteroposterior X-rays. The intraclass correlation coefficients of cup positioning angles were calculated (inclination: 0.92, anteversion: 0.89 for intra-observer agreement; inclination: 0.91, anteversion: 0.85 for inter-observer agreement). Complications were defined as dislocation, periprosthetic fracture, ankle fracture, implant loosening, nerve injury, surgical site infection, deep vein thrombosis, and revision surgery for any reason.

resultsRadiographic analysis showed an average cup inclination of 38.1° ± 4.1° (99.0% within Lewinnek's safe zone). The average cup anteversion was 12.0° ± 4.7° (97.0% within Lewinnek's safe zone). None of the patients experienced any complications.

conclusionThe use of a conventional traction table to perform THA using fluoroscopy may not interfere with precise cup positioning. This technique, which does not require a special carbon fiber traction table for THA, could be a feasible alternative for performing THA at general hospitals.

Indexed as

Component positioningComponent safe zoneDirect anterior approachFluoroscopyTotal hip arthroplasty

Identifiers

PMID39915885
PMCPMC11804042

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.