Evidence map›Paper›PMID 39915306›Full record

ArticleClinical neuroradiology2025

In Vivo Discrimination of Iodine and Tantalum-Based Liquid Embolics After Intracranial or Spinal Embolization Using Photon-Counting Detector CT.

Christoph Johannes Maurer, Ansgar Berlis, Franz Josef Stangl, Lars Behrens

Abstract read
In one paragraph

Article in Clinical neuroradiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Christoph Johannes MaurerDepartment of Diagnostic and Interventional Neuroradiology, University Hospital Augsburg, Stenglinstraße 2, 86156, Augsburg, Germany. Christoph.Maurer@uk-augsburg.de.ORCID http://orcid.org/0000-0002-0305-0797
Ansgar BerlisDepartment of Diagnostic and Interventional Neuroradiology, University Hospital Augsburg, Stenglinstraße 2, 86156, Augsburg, Germany.ORCID http://orcid.org/0000-0001-5321-5118
Franz Josef StanglDepartment of Diagnostic and Interventional Neuroradiology, University Hospital Augsburg, Stenglinstraße 2, 86156, Augsburg, Germany.ORCID http://orcid.org/0009-0005-6347-7580
Lars BehrensDepartment of Diagnostic and Interventional Neuroradiology, University Hospital Augsburg, Stenglinstraße 2, 86156, Augsburg, Germany.ORCID http://orcid.org/0000-0002-3221-6055

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIn vitro differentiation of iodine and tantalum-based liquid embolics post-embolization can be achieved using spectral computed tomography. This study evaluates the in vivo ability of clinical photon-counting computed tomography (PCD-CT) to distinguish these embolic agents in patients undergoing endovascular treatments for cerebrovascular and spinal pathologies.

methodsThis retrospective study included 25 patients treated between April 2021 and March 2024, who underwent PCD-CT imaging post-embolization for intracranial arteriovenous malformations (AVM), dural arteriovenous fistulas (dAVF), spinal tumors, or middle meningeal artery (MMA) embolization for chronic subdural hematomas (cSDH). Imaging analysis involved iterative reconstruction, using conventional images (CI), iodine maps (IM), and virtual non-contrast (VNC) series. Two blinded neuroradiologists assessed the suppression quality of the embolic agents on a Likert scale.

resultsOf the 25 patients, 22 underwent intracranial and 3 spinal embolizations. The differentiation between iodine and tantalum-based embolics achieved 92% accuracy for reader 1 and 88% for reader 2, with a Cohen's kappa coefficient of 0.92 indicating high inter-reader agreement. Iodine-based agents were moderately suppressed, whereas tantalum-based agents exhibited superior suppression. Errors arose from mistaking suppressed platinum coils for tantalum-based embolics. Hemorrhage detection accuracy was high, with a Cohen's kappa of 0.92.

conclusionsPCD-CT effectively differentiates between iodine- and tantalum-based embolics in vivo, demonstrating high diagnostic accuracy and inter-reader reliability. This capability facilitates improved post-procedural assessment and may enhance the management of endovascularly treated patients by reducing imaging artifacts and aiding in hemorrhage detection.

Indexed as

Embolization, TherapeuticIodineTantalumTomography, X-Ray ComputedAdultAgedFemaleHumansIntracranial Arteriovenous MalformationsMaleMiddle AgedRetrospective StudiesIodineTantalumIntracranial and spinal embolizationIodine-based embolicsMaterial decompositionPhoton-counting CTTantalum-based embolics

Identifiers

PMID39915306
PMCPMC12454468

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.