Evidence map›Paper›PMID 39913115›Full record

ReviewPacing and clinical electrophysiology : PACE2026

Fundamentals of System Design for Cardiac Pulsed Field Ablation: Optimization of Safety, Efficacy, and Usability.

Brendan Koop

Abstract readReview
In one paragraph

Review in Pacing and clinical electrophysiology : PACE, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Brendan KoopElectrophysiology Research & Development, Boston Scientific Corporation, Marlborough, Massachusetts, USA.ORCID 0009-0006-5786-627X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The goal of a cardiac pulsed field ablation (PFA) system is to provide safe, effective, and usable therapy for the treatment of cardiac arrhythmias. Achieving this goal is a complex exercise in system design, requiring optimization of catheter, waveform, and dosing. This optimization is often iterative, as myriad design factors are balanced to achieve the goal while making use of computational modeling, bench testing, preclinical animal studies, and human clinical studies to evaluate system performance. It is important for both engineers and clinicians to understand the fundamentals of cardiac PFA system design in order to partner to continuously improve performance of this expanding ablation modality.

Indexed as

Arrhythmias, CardiacCatheter AblationAnimalsEquipment DesignHumansTreatment Outcomecardiaccatheterdosingelectroporationpulsed field ablationsystem designwaveform