Evidence map›Paper›PMID 39913103›Full record

ArticleInternational braz j urol : official journal of the Brazilian Society of Urology

Mixed Reality Ultrasound-Guided Mini-ECIRS with Apple Vision Pro™ - First Case Report.

Roberto Montoro, Fabio C Vicentini, Ricardo T S Ugino, Alexandre Danilovic, Giovanni S Marchini, Fabio C M Torricelli, Carlos A Batagello, Anderson B Pellanda, Alexandre Silva, William C Nahas and 1 more

Abstract readCase ReportsVideo-Audio Media
In one paragraph

Article in International braz j urol : official journal of the Brazilian Society of Urology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Roberto MontoroDivisão de Urologia, Hospital Ana Costa, Santos, SP, Brasil.
Fabio C VicentiniDivisão de Urologia, Hospital Israelita Albert Einstein, São Paulo, SP, Brasil.
Ricardo T S UginoDivisão de Urologia, Hospital das Clínicas Universidade de São Paulo - USP, São Paulo, SP, Brasil.
Alexandre DanilovicDivisão de Urologia, Hospital das Clínicas Universidade de São Paulo - USP, São Paulo, SP, Brasil.
Giovanni S MarchiniDivisão de Urologia, Hospital das Clínicas Universidade de São Paulo - USP, São Paulo, SP, Brasil.
Fabio C M TorricelliDivisão de Urologia, Hospital das Clínicas Universidade de São Paulo - USP, São Paulo, SP, Brasil.
Carlos A BatagelloDivisão de Urologia, Hospital das Clínicas Universidade de São Paulo - USP, São Paulo, SP, Brasil.
Anderson B PellandaDivisão de Urologia, Hospital das Clínicas Universidade de São Paulo - USP, São Paulo, SP, Brasil.
Alexandre SilvaDivisão de Urologia da Universidade Federal do Paraná - UFPR, Curitiba, PR, Brasil.
William C NahasDivisão de Urologia, Hospital das Clínicas Universidade de São Paulo - USP, São Paulo, SP, Brasil.
Eduardo MazzucchiDivisão de Urologia, Hospital das Clínicas Universidade de São Paulo - USP, São Paulo, SP, Brasil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionSome endourological surgeries require multiple screens to perform combined procedures, which can present ergonomic challenges (1, 2). Apple Vision Pro (AVP) is a spatial computing device developed by Apple that incorporates virtual reality (VR) for life-like simulations, realistic medical scenarios, interactive anatomical models, and augmented reality (AR) technologies (3). In health care, VR is used for pain management, physical therapy, psychological therapy, and surgical simulations, providing a controlled and safe environment for both patients and healthcare professionals (4).

objectiveTo demonstrate the step-by-step technique of the Mini-Endoscopic Combined Intra-Renal Surgery (Mini-ECIRS) procedure guided by ultrasound and using mixed reality technology with the Apple Vision Pro (multiscreen and 3D reconstruction). To the best of our knowledge, this is the first report of this procedure being performed with AVP assistance. PATIENT AND

methodsWe present the case of a 40-year-old female with a history of right lumbar pain for one year. A CT scan revealed a proximal ureteral stone (20mm) and a lower pole stone (14mm) on the right side, with a Guys's Score grade 2 4. In this case, we opted for Ultrasound-Guided Mini-ECIRS (5, 6). This choice allowed for precise puncture and dilation, ensuring effective treatment and minimal invasiveness, assisted by the Apple Vision Pro. This device is equipped with eight external cameras that capture the real world at a resolution of 4K, enhancing the surgeon's experience with unparalleled efficiency and ease of mixed reality. This advanced imaging allows for precise visualization and integration of digital elements into the physical environment, significantly improving the accuracy and effectiveness of surgical procedures. During this procedure, the multitude of equipment in the operating room often obstructs the view of the physical monitors, including ultrasound. However, this technology addresses these challenges by offering enhanced ergonomics, efficiency, and safety to the surgeon. By providing seamless integration of digital overlays and real-world visuals, it ensures that crucial information is always within the surgeon's line of sight, thereby improving operational precision and overall outcomes. The surgeon had no previous contact with the AVP and was assisted by an AVP expert urologist throughout the procedure.

resultsThe procedure was performed in the Barts flank-free position. Initially, ureterolithotomy was performed using holmium laser. After the dusting phase, an ultrasound-guided renal puncture was performed using a virtual screen, providing enhanced comfort and ergonomics for the surgeon. Throughout the procedure, the surgeon had simultaneous access to both screens (nephroscope and flexible ureteroscope), facilitating efficient location of any residual stones. The AVP functioned effectively, displaying multiple screens within its own interface, improving ergonomics during surgery and maintaining safety throughout the procedure. The surgery was performed uneventfully in 2 hours, and the patient was rendered stone-free on CT and was discharged on the first postoperative day.

conclusionApple Vision Pro provides multiscreen and 3D reconstruction capabilities, ensuring a comfortable, safe, and easily replicable procedure. Its advanced technology may be particularly beneficial for surgeries, such as Mini-ECIRS, which require simultaneous screens.

Indexed as

Augmented RealitySurgery, Computer-AssistedUltrasonography, InterventionalUreteral CalculiVirtual RealityAdultFemaleHumansImaging, Three-Dimensional

Identifiers

PMID39913103
PMCPMC11884634

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.