Evidence map›Paper›PMID 39912071›Full record

ArticleClinics in orthopedic surgery2025

Does the Proximal Humerus Nail with 2 Distal Screws Provide Sufficient Rotational Stability?

Ki Yong An, Tae Gyu Park, Min Young Kim

Abstract read
In one paragraph

Article in Clinics in orthopedic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Comparison of fluoroscopic versus electromagnetic distal locking in humeral shaft osteosynthesis using intramedullary nail: a retrospective study.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Ki Yong AnDepartment of Orthopedic Surgery, Kwangju Christian Hospital, Gwangju, Korea.ORCID https://orcid.org/0000-0003-3583-6425
Tae Gyu ParkDepartment of Orthopedic Surgery, Kwangju Christian Hospital, Gwangju, Korea.ORCID https://orcid.org/0000-0002-6100-6268
Min Young KimDepartment of Orthopedic Surgery, Kwangju Christian Hospital, Gwangju, Korea.ORCID https://orcid.org/0000-0003-3073-5481

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Backgroud: Proximal humerus nails, frequently used for managing proximal humerus fractures, significantly enhance rotational stability and reinforce fractured fragments. Few research exists regarding the optimal number and positioning of distal screws. This study aimed to assess the stability of diverse screw configurations and scrutinize screw distribution and bone stress via finite element analysis. Methods: The humerus intramedullary nail (Humerus Interlocking Nail System; TDM) underwent assessment using finite element analysis applied to a humerus model. Three groups were established based on varying distal screw numbers and locations: all 3 distal locking holes were used in group 1; 2 screws (dynamic hole and proximal static hole) in group 2, and 2 screws (dynamic hole and distal static hole) in group 3. Finite element analysis computed stress distribution within the implant and bone for each group. A 1-mm fracture gap was simulated at the surgical neck, and stress distributions were analyzed in both normal and osteoporotic bone models. Results: Using two screws did not compromise rotational stability. Stress distribution analysis revealed stability across all groups without reaching failure strength. Group 3 exhibited a minor rise in component 11 (direct stress [force per unit area] acting on the positive and negative 1 faces in the 1-axis. direction) and component 22 (direct stress [force per unit area] acting on the positive and negative 2 faces in the 2-axis direction) stress, remaining below failure strength thresholds. Group 1 exhibited the lowest von Mises stress in the nail and screws, while groups 2 and 3 did not reach failure strength levels. Findings remained consistent in the osteoporotic model. Conclusions: All 3 groups demonstrated rotational stability concerning stress distribution, indicating that using 2 screws for distal fixation does not adversely affect stability. This suggests the potential for saving surgical time and reducing radiation exposure without compromising stability.

Indexed as

Bone NailsBone ScrewsFracture Fixation, IntramedullaryShoulder FracturesBiomechanical PhenomenaFinite Element AnalysisHumansRotationStress, MechanicalFinite element analysisFractureHumerusIntramedullary nailProximal humerus fracture

Identifiers

PMID39912071
PMCPMC11791494

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.