ArticleClinics in orthopedic surgery2025
Mechanical Effects of Offset and Length of the Cementless Stem for Initial Fixation to the Femur.
Article in Clinics in orthopedic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Backgroud: Implants with different neck offsets for hip replacement surgery are now available from various implant manufacturers and have become a widely used option for achieving postoperative hip stability. This study aimed to compare the impact of neck offset on initial stem fixation and the mechanical effects of different stem lengths when using cementless stems. Methods: We performed a finite element analysis using Mechanical Finder ver. 12.0. CAD models of the Profemur Preserve and Profemur TL cementless stems. Each stem was appropriately sized, and the von Mises stress was calculated. We defined micromotion as the relative displacement between the stem node and the surface of bone contact. The maximum micromotion values of these finite element models were compared under standing conditions. Results: The stress per zone for both stems (Preserve and TL) was the highest in zone 5, followed by zones 3 and 4, which were almost in line with each other. The high offset (HIGH) stress was higher than the standard offset (STD) stress in each stem and zone. The micromotion of each stem was higher at each load in the following order: Preserve HIGH, Preserve STD, TL HIGH, and TL STD, with HIGH being higher than STD at each stem. Conclusions: The choice of higher offset or shorter length stems induced higher micromotion at the interface to the bone in the early postoperative period. Therefore, surgeons should be more careful to get appropriate initial fixation using shorter stems with higher offset necks due to the relatively high incidence of loosening or fractures.