Evidence map›Paper›PMID 39912065›Full record

ArticleClinics in orthopedic surgery2025

Mechanical Effects of Offset and Length of the Cementless Stem for Initial Fixation to the Femur.

Yutaro Shibuta, Nobuhiro Kaku, Kensei Tanaka, Tsuguaki Hosoyama

Abstract read
In one paragraph

Article in Clinics in orthopedic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yutaro ShibutaDepartment of Orthopaedic Surgery, Faculty of Medicine, Oita University, Yufu City, Japan.ORCID https://orcid.org/0000-0001-5555-0905
Nobuhiro KakuDepartment of Orthopaedic Surgery, Faculty of Medicine, Oita University, Yufu City, Japan.ORCID https://orcid.org/0000-0002-4041-1870
Kensei TanakaDepartment of Orthopaedic Surgery, Faculty of Medicine, Oita University, Yufu City, Japan.ORCID https://orcid.org/0009-0002-2297-9056
Tsuguaki HosoyamaDepartment of Orthopaedic Surgery, Faculty of Medicine, Oita University, Yufu City, Japan.ORCID https://orcid.org/0000-0002-8505-6534

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Backgroud: Implants with different neck offsets for hip replacement surgery are now available from various implant manufacturers and have become a widely used option for achieving postoperative hip stability. This study aimed to compare the impact of neck offset on initial stem fixation and the mechanical effects of different stem lengths when using cementless stems. Methods: We performed a finite element analysis using Mechanical Finder ver. 12.0. CAD models of the Profemur Preserve and Profemur TL cementless stems. Each stem was appropriately sized, and the von Mises stress was calculated. We defined micromotion as the relative displacement between the stem node and the surface of bone contact. The maximum micromotion values of these finite element models were compared under standing conditions. Results: The stress per zone for both stems (Preserve and TL) was the highest in zone 5, followed by zones 3 and 4, which were almost in line with each other. The high offset (HIGH) stress was higher than the standard offset (STD) stress in each stem and zone. The micromotion of each stem was higher at each load in the following order: Preserve HIGH, Preserve STD, TL HIGH, and TL STD, with HIGH being higher than STD at each stem. Conclusions: The choice of higher offset or shorter length stems induced higher micromotion at the interface to the bone in the early postoperative period. Therefore, surgeons should be more careful to get appropriate initial fixation using shorter stems with higher offset necks due to the relatively high incidence of loosening or fractures.

Indexed as

Arthroplasty, Replacement, HipFemurHip ProsthesisProsthesis DesignBiomechanical PhenomenaFinite Element AnalysisHumansStress, MechanicalFemurFinite element analysisTotal hip arthroplasty

Identifiers

PMID39912065
PMCPMC11791486

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.