ArticlePsychophysiology2025
Quality in Question: Assessing the Accuracy of Four Heart Rate Wearables and the Implications for Psychophysiological Research.
Article in Psychophysiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Exercise Training and Heart Rate Variability: A Guided Optimization of Cardiorespiratory Fitness in Cardiometabolic Disease.Current atherosclerosis reports · 2026Review
- The WISH 2.0 Intervention for Irritable Bowel Syndrome: Protocol for a Pilot Randomized Controlled Trial.JMIR research protocols · 2026Article
- Standardized synchronization and validation pipeline for physiological biomarkers across multiple devices.Behavior research methods · 2026Article
- Reliability Assessment of Wearable Technologies for Physiological Measurements: An Evaluation of Shimmer3 GSR+, Empatica E4, EmbracePlus, and Pixel Watch 2 Across Cognitive, Affective and Physical Activity Tasks.Sensors (Basel, Switzerland) · 2026Article
- The Impact of Self-Managed Virtual Reality Relaxation on Non-invasive Ambulatory Physiological Markers in Home-Based Psychiatric Care.Applied psychophysiology and biofeedback · 2026Article
- Combining self-regulation and poverty reduction to prevent depression and anxiety among adolescents experiencing multi-dimensional poverty in Colombia, Nepal and South Africa: study protocol of a pilot 4-arm cluster randomised controlled trial.Pilot and feasibility studies · 2026Article
- Resting Heart Rate Variability Measured by Consumer Wearables and Its Associations with Diverse Health Domains in Five Longitudinal Studies.Sensors (Basel, Switzerland) · 2025Article
- Butterworth Filtering at 500 Hz Optimizes PPG-Based Heart Rate Variability Analysis for Wearable Devices: A Comparative Study.Sensors (Basel, Switzerland) · 2025Article
- Rethinking Resting Heart Rate Variability: No Evidence of Association With Self-Regulation and Psychopathology in a Cross-Sectional Study Among Adolescents in Colombia, Nepal, and South Africa.Psychophysiology · 2025Article
- LOTUS Software to Process Wearable EmbracePlus Data.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Heart rate (HR) and heart rate variability (HRV) are two key measures with significant relevance in psychophysiological studies, and their measurement has become more convenient due to advances in wearable technology. However, photoplethysmography (PPG)-based wearables pose critical validity concerns. In this study, we validated four PPG wearables: three consumer-grade devices (Kyto2935, Schone Rhythm 24, and HeartMath Inner Balance Bluetooth) and one research-grade device (Empatica EmbracePlus, successor to the widely-used but discontinued Empatica E4). All devices were worn simultaneously by 40 healthy participants who underwent conditions commonly used in laboratory research (seated rest, arithmetic task, recovery, slow-paced breathing, a neuropsychological task, posture manipulation by standing up) and encountered in ambulatory-like settings (slow walking and stationary biking), compared against a criterion electrocardiography device, the Vrije Universiteit Ambulatory Monitoring System (VU-AMS). We determined the signal quality, the linear strength through regression analysis, the bias through Bland-Altman analysis, and the measurement error through mean arctangent absolute percentage error for each condition against the criterion device. We found that the research-grade device did not outperform the consumer-grade devices in laboratory conditions. It also showed low agreement with the ECG in ambulatory-like conditions. In general, devices captured HR more accurately than HRV. Finally, conditions that deviated from baseline settings and involved slight to high movement, negatively impacted the agreement between PPG devices and the criterion. We conclude that PPG devices, even those advertised and designed for research purposes, may pose validity concerns for HRV measurement in conditions other than those similar to resting states.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.