Evidence map›Paper›PMID 39905563›Full record

ArticlePsychophysiology2025

Quality in Question: Assessing the Accuracy of Four Heart Rate Wearables and the Implications for Psychophysiological Research.

Mohammadamin Sinichi, Martin J Gevonden, Lydia Krabbendam

Abstract read
In one paragraph

Article in Psychophysiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. LOTUS Software to Process Wearable EmbracePlus Data.Sensors (Basel, Switzerland) · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Mohammadamin SinichiDepartment of Clinical, Neuro- & Developmental Psychology, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.ORCID 0009-0008-2491-1542
Martin J GevondenInstitute Brain and Behaviour (iBBA), Amsterdam, The Netherlands.ORCID 0000-0001-7867-1443
Lydia KrabbendamDepartment of Clinical, Neuro- & Developmental Psychology, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.ORCID 0000-0003-4074-5149

Funding

Wellcome TrustWellcome Trust 221940/Z/20/Z
6 · The paper itself

Abstract

Heart rate (HR) and heart rate variability (HRV) are two key measures with significant relevance in psychophysiological studies, and their measurement has become more convenient due to advances in wearable technology. However, photoplethysmography (PPG)-based wearables pose critical validity concerns. In this study, we validated four PPG wearables: three consumer-grade devices (Kyto2935, Schone Rhythm 24, and HeartMath Inner Balance Bluetooth) and one research-grade device (Empatica EmbracePlus, successor to the widely-used but discontinued Empatica E4). All devices were worn simultaneously by 40 healthy participants who underwent conditions commonly used in laboratory research (seated rest, arithmetic task, recovery, slow-paced breathing, a neuropsychological task, posture manipulation by standing up) and encountered in ambulatory-like settings (slow walking and stationary biking), compared against a criterion electrocardiography device, the Vrije Universiteit Ambulatory Monitoring System (VU-AMS). We determined the signal quality, the linear strength through regression analysis, the bias through Bland-Altman analysis, and the measurement error through mean arctangent absolute percentage error for each condition against the criterion device. We found that the research-grade device did not outperform the consumer-grade devices in laboratory conditions. It also showed low agreement with the ECG in ambulatory-like conditions. In general, devices captured HR more accurately than HRV. Finally, conditions that deviated from baseline settings and involved slight to high movement, negatively impacted the agreement between PPG devices and the criterion. We conclude that PPG devices, even those advertised and designed for research purposes, may pose validity concerns for HRV measurement in conditions other than those similar to resting states.

Indexed as

Heart RatePhotoplethysmographyPsychophysiologyWearable Electronic DevicesAdultElectrocardiographyFemaleHumansMaleReproducibility of ResultsYoung Adult

Identifiers

PMID39905563
PMCPMC11794680

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.