In Vivo Bone Mineral Density Assessment With Spectral Localizer Radiographs From Photon-Counting Detector CT: Prospective Comparison With DXA.

Lukas Jakob Moser, Konstantin Klambauer, Maria Carolina Diaz Machicado, Diana Frey, Victor Mergen, Matthias Eberhard, Tristan Nowak, Bernhard Schmidt, Thomas Flohr, Oliver Distler and 1 more

Abstract readComparative Study
In one paragraph

Article in Investigative radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Lukas Jakob MoserFrom the Department of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (L.J.M., K.M., V.M., M.E., T.F., H.A.); Department of Rheumatology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (M.C.D.M., D.F., O.D.); Siemens Healthineers AG, Forchheim, Germany (T.N., B.S., T.F.); and Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, the Netherlands (T.F.).
Konstantin Klambauer
Maria Carolina Diaz Machicado
Diana Frey
Victor Mergen
Matthias Eberhard
Tristan Nowak
Bernhard Schmidt
Thomas Flohr
Oliver Distler

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of this study was to determine in a prospective patient study the accuracy of areal bone mineral density (aBMD) measurements with spectral localizer radiographs obtained with a clinical photon-counting detector computed tomography (PCD-CT) scanner in comparison with dual-energy x-ray absorptiometry (DXA).

methodsIn this institutional review board-approved, prospective study, 41 patients (15 females, 26 males; mean age 61.3 years, age range 35-78 years) underwent PCD-CT of the abdomen with a spectral localizer radiograph (tube voltage 140 kVp, tube current 30 mA) and DXA within a median of 45 days. aBMD values were derived for lumbar vertebrae L1-L4 from both methods and were compared with linear regression, Pearson correlation, intraclass correlation coefficients (ICCs), and Bland-Altman plots. T-scores were calculated on a patient level and were compared between methods.

resultsDXA and spectral localizer radiographs showed strong correlation in aBMD measurements ( R = 0.97, P < 0.001) and patient level T-scores ( R = 0.99, P < 0.001). There was a strong agreement between aBMD from both methods (ICC, 0.96; 95% CI, 0.94-0.97). Bland-Altman analysis revealed a very small mean difference in aBMD between methods (mean absolute error 0.019 g/cm 2 ) with narrow limits of agreement (-0.083 g/cm 2 to 0.121 g/cm 2 ). Similarly, there were small differences in regard to the T-score (mean absolute error 0.156) with narrow limits of agreement (-0.422 to 0.734) between methods. ICCs indicated an excellent agreement between T-scores from DXA and spectral localizer radiographs (ICC, 0.98; 95% confidence interval, 0.95-0.99).

conclusionsOur prospective patient study indicates that spectral localizer radiographs obtained with a clinical PCD-CT system enable accurate quantification of the lumbar bone areal mineral density. This opens up the opportunity for opportunistic screening of osteoporosis in patients who undergo CT for other indications.

Indexed as

Absorptiometry, PhotonBone DensityOsteoporosisTomography, X-Ray ComputedAdultAgedFemaleHumansLumbar VertebraeMaleMiddle AgedProspective StudiesReproducibility of ResultsSensitivity and Specificitybone mineral densitycomputed tomographylocalizer radiographsphoton-counting detectorspectral imaging

Identifiers

PMID39899807
PMCPMC12233169

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.